3COM CORPORATION
US ROBOTICS NETSERVER I-MODEM/16
Card Type | Modem (asynchronous) |
Chip Set | Unidentified |
Maximum Modem Rate | 33.6Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Modulation Protocol | Unidentified |
Fax Modulation Protocol | Unidentified |
Error Correction/Compression | Unidentified |
Fax Class | Class I & II |
Data Bus | External |

CONNECTIONS | ||||||
Function | Label | Function | Label | |||
DC power | CN1 | RJ-45 jack channel 5/6 | CN7 | |||
RJ-45 jack channel 1/2 | CN3 | RJ-45 auxiliary connector | CN8 | |||
RJ-45 jack channel 3/4 | CN4 | RJ-45 console connector | CN9 | |||
BNC network connector | CN5 | RJ-45 jack channel 7/8 | CN10 | |||
RJ-45 network connector | CN6 | Power switch | SW1 | |||
Note: CN3, CN4, CN7, CN10 accept either RJ-11 or RJ-45 connectors. | ||||||
USER CONFIGURABLE SETTINGS | ||
Setting | Label | Position |
Load defaults from NVRAM | SW1/1 | Off |
Load defaults from ROM | SW1/1 | On |
Command odd set recognition disabled | SW1/2 | Off |
Command odd set recognition enabled | SW1/2 | On |
Factory configured - do not alter | SW1/3 | Unidentified |
Factory configured - do not alter | SW1/4 | Unidentified |
Use software configured baud rate | SW2/3 | Off |
Force DIP switch rate | SW2/3 | On |
Normal flash memory operation | SW2/4 | Off |
Erase flash memory on boot-up | SW2/4 | On |
Factory configured - do not alter | SW2/5-10 | Unidentified |
CONSOLE PORT BAUD RATE | ||
Rate | SW2/1 | SW2/2 |
9600bps | Off | Off |
19.2Kbps | Off | On |
38.4Kbps | On | Off |
57.6Kbps | On | On |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
LED1 | Off | Off | Power off |
LED1 | Green | On | Power on |
LED1 | Red | On | Critical failure |
LED2 | Off | Off | Channel 1 idle |
LED2 | Green | On | Channel 1 on-line |
LED2 | Green | Blinking | Channel 1 testing data link layer |
LED2 | Yellow | Blinking (8 times/sec.) | Channel 1 searching for U interface |
LED2 | Yellow | Blinking (1 times/sec.) | Channel 1 searching for S/T interface |
LED2 | Yellow | On | Channel 1 dialing |
LED2 | Red | On | Channel 1 U interface not found |
LED2 | Red | Blinking | Channel 1 incorrect SPID |
LED3 | Off | Off | Channel 2 idle |
LED3 | Green | On | Channel 2 on-line |
LED3 | Green | Blinking | Channel 2 testing data link layer |
LED3 | Yellow | Blinking (8 times/sec.) | Channel 2 searching for U interface |
LED3 | Yellow | Blinking (1 times/sec.) | Channel 2 searching for S/T interface |
LED3 | Yellow | On | Channel 2 dialing |
LED3 | Red | On | Channel 2 U interface not found |
LED3 | Red | Blinking | Channel 2 incorrect SPID |
DIAGNOSTIC LED(S) (CON’T) | |||
LED | Color | Status | Condition |
LED4 | Off | Off | Channel 3 idle |
LED4 | Green | On | Channel 3 on-line |
LED4 | Green | Blinking | Channel 3 testing data link layer |
LED4 | Yellow | Blinking (8 times/sec.) | Channel 3 searching for U interface |
LED4 | Yellow | Blinking (1 times/sec.) | Channel 3 searching for S/T interface |
LED4 | Yellow | On | Channel 3 dialing |
LED4 | Red | On | Channel 3 U interface not found |
LED4 | Red | Blinking | Channel 3 incorrect SPID |
LED5 | Off | Off | Channel 4 idle |
LED5 | Green | On | Channel 4 on-line |
LED5 | Green | Blinking | Channel 4 testing data link layer |
LED5 | Yellow | Blinking (8 times/sec.) | Channel 4 searching for U interface |
LED5 | Yellow | Blinking (1 times/sec.) | Channel 4 searching for S/T interface |
LED5 | Yellow | On | Channel 4 dialing |
LED5 | Red | On | Channel 4 U interface not found |
LED5 | Red | Blinking | Channel 4 incorrect SPID |
LED6 | Off | Off | Channel 5 idle |
LED6 | Green | On | Channel 5 on-line |
LED6 | Green | Blinking | Channel 5 testing data link layer |
LED6 | Yellow | Blinking (8 times/sec.) | Channel 5 searching for U interface |
LED6 | Yellow | Blinking (1 times/sec.) | Channel 5 searching for S/T interface |
LED6 | Yellow | On | Channel 5 dialing |
LED6 | Red | On | Channel 5 U interface not found |
LED6 | Red | Blinking | Channel 5 incorrect SPID |
LED7 | Off | Off | Channel 6 idle |
LED7 | Green | On | Channel 6 on-line |
LED7 | Green | Blinking | Channel 6 testing data link layer |
LED7 | Yellow | Blinking (8 times/sec.) | Channel 6 searching for U interface |
LED7 | Yellow | Blinking (1 times/sec.) | Channel 6 searching for S/T interface |
LED7 | Yellow | On | Channel 6 dialing |
LED7 | Red | On | Channel 6 U interface not found |
LED7 | Red | Blinking | Channel 6 incorrect SPID |
LED8 | Off | Off | Channel 7 idle |
LED8 | Green | On | Channel 7 on-line |
LED8 | Green | Blinking | Channel 7 testing data link layer |
LED8 | Yellow | Blinking (8 times/sec.) | Channel 7 searching for U interface |
LED8 | Yellow | Blinking (1 times/sec.) | Channel 7 searching for S/T interface |
LED8 | Yellow | On | Channel 7 dialing |
LED8 | Red | On | Channel 7 U interface not found |
LED8 | Red | Blinking | Channel 7 incorrect SPID |
DIAGNOSTIC LED(S) (CON’T) | |||
LED | Color | Status | Condition |
LED9 | Off | Off | Channel 8 idle |
LED9 | Green | On | Channel 8 on-line |
LED9 | Green | Blinking | Channel 8 testing data link layer |
LED9 | Yellow | Blinking (8 times/sec.) | Channel 8 searching for U interface |
LED9 | Yellow | Blinking (1 times/sec.) | Channel 8 searching for S/T interface |
LED9 | Yellow | On | Channel 8 dialing |
LED9 | Red | On | Channel 8 U interface not found |
LED9 | Red | Blinking | Channel 8 incorrect SPID |
LED10 | Red | On | POST test |
LED10 | Green | Blinking (1 times/sec.) | checking for software download |
LED10 | Green | Blinking (8 times/sec.) | loading NETserver application into RAM |
LED10 | Green | On | normal operation |
LED11 | Red | On | POST |
LED11 | Green | On | Erasing flash memory |
LED11 | Amber | On | Programming flash memmory |
LED11 | Off | Off | Normal |
LED12 | Red | On | Interface failure |
LED12 | Green | On | Transmitting packet |
LED12 | Off | Off | Idle |
LED13 | Red | On | Interface failure |
LED13 | Green | On | Receiving packet |
LED13 | Off | Off | Idle |
LED14 | Red | Blinking | Collision (1 blink per collision) |
LED14 | Green | On | 10 base-T link detected |
LED14 | Off | Off | 10 base-2 link connection (If 10 base-T is being used, this indicates a bad link) |
LED15 | Green | Blinking | Characters being received/transmitted through serial port |
LED15 | Off | Off | Serial port idle |
LED16 | Off | Off | Power off |
LED16 | Green | On | Power on |
LED16 | Red | On | Critical failure |
LED17 | Off | Off | Channel 1 idle |
LED17 | Green | On | Channel 1 on-line |
LED17 | Green | Blinking | Channel 1 testing data link layer |
LED17 | Yellow | Blinking (8 times/sec.) | Channel 1 searching for U interface |
LED17 | Yellow | Blinking (1 times/sec.) | Channel 1 searching for S/T interface |
LED17 | Yellow | On | Channel 1 dialing |
LED17 | Red | On | Channel 1 U interface not found |
LED17 | Red | Blinking | Channel 1 incorrect SPID |
DIAGNOSTIC LED(S) (CON’T) | |||
LED | Color | Status | Condition |
LED18 | Off | Off | Channel 2 idle |
LED18 | Green | On | Channel 2 on-line |
LED18 | Green | Blinking | Channel 2 testing data link layer |
LED18 | Yellow | Blinking (8 times/sec.) | Channel 2 searching for U interface |
LED18 | Yellow | Blinking (1 times/sec.) | Channel 2 searching for S/T interface |
LED18 | Yellow | On | Channel 2 dialing |
LED18 | Red | On | Channel 2 U interface not found |
LED18 | Red | Blinking | Channel 2 incorrect SPID |
LED19 | Off | Off | Channel 3 idle |
LED19 | Green | On | Channel 3 on-line |
LED19 | Green | Blinking | Channel 3 testing data link layer |
LED19 | Yellow | Blinking (8 times/sec.) | Channel 3 searching for U interface |
LED19 | Yellow | Blinking (1 times/sec.) | Channel 3 searching for S/T interface |
LED19 | Yellow | On | Channel 3 dialing |
LED19 | Red | On | Channel 3 U interface not found |
LED19 | Red | Blinking | Channel 3 incorrect SPID |
LED20 | Off | Off | Channel 4 idle |
LED20 | Green | On | Channel 4 on-line |
LED20 | Green | Blinking | Channel 4 testing data link layer |
LED20 | Yellow | Blinking (8 times/sec.) | Channel 4 searching for U interface |
LED20 | Yellow | Blinking (1 times/sec.) | Channel 4 searching for S/T interface |
LED20 | Yellow | On | Channel 4 dialing |
LED20 | Red | On | Channel 4 U interface not found |
LED20 | Red | Blinking | Channel 4 incorrect SPID |
LED21 | Off | Off | Channel 5 idle |
LED21 | Green | On | Channel 5 on-line |
LED21 | Green | Blinking | Channel 5 testing data link layer |
LED21 | Yellow | Blinking (8 times/sec.) | Channel 5 searching for U interface |
LED21 | Yellow | Blinking (1 times/sec.) | Channel 5 searching for S/T interface |
LED21 | Yellow | On | Channel 5 dialing |
LED21 | Red | On | Channel 5 U interface not found |
LED21 | Red | Blinking | Channel 5 incorrect SPID |
LED22 | Off | Off | Channel 6 idle |
LED22 | Green | On | Channel 6 on-line |
LED22 | Green | Blinking | Channel 6 testing data link layer |
LED22 | Yellow | Blinking (8 times/sec.) | Channel 6 searching for U interface |
LED22 | Yellow | Blinking (1 times/sec.) | Channel 6 searching for S/T interface |
LED22 | Yellow | On | Channel 6 dialing |
LED22 | Red | On | Channel 6 U interface not found |
LED22 | Red | Blinking | Channel 6 incorrect SPID |
DIAGNOSTIC LED(S) (CON’T) | |||
LED | Color | Status | Condition |
LED23 | Off | Off | Channel 7 idle |
LED23 | Green | On | Channel 7 on-line |
LED23 | Green | Blinking | Channel 7 testing data link layer |
LED23 | Yellow | Blinking (8 times/sec.) | Channel 7 searching for U interface |
LED23 | Yellow | Blinking (1 times/sec.) | Channel 7 searching for S/T interface |
LED23 | Yellow | On | Channel 7 dialing |
LED23 | Red | On | Channel 7 U interface not found |
LED23 | Red | Blinking | Channel 7 incorrect SPID |
LED24 | Off | Off | Channel 8 idle |
LED24 | Green | On | Channel 8 on-line |
LED24 | Green | Blinking | Channel 8 testing data link layer |
LED24 | Yellow | Blinking (8 times/sec.) | Channel 8 searching for U interface |
LED24 | Yellow | Blinking (1 times/sec.) | Channel 8 searching for S/T interface |
LED24 | Yellow | On | Channel 8 dialing |
LED24 | Red | On | Channel 8 U interface not found |
LED24 | Red | Blinking | Channel 8 incorrect SPID |
SUPPORTED COMMAND SET |
Basic AT Commands |
AT, ‘+++’, A/ |
A, B, C, E, F, O, V |
&C, &G, &W, &Z |
S Registers |
S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S18, S26 |
Note: See MHI Help File for full command documentation. |
Proprietary AT Command Set
HELP | |
Type: | Configuration |
Format: | AT [cmds] #$ [cmds] |
Description: | Display the help pannels for the octothorpe (#) command set |
ADDITIONASL RESULT CODES | |
Type: | Configuration |
Format: | AT [cmds] &An [cmds] |
Description: | Controls the display of the additional result codes |
Command | Function |
í &A0 | Do not display ARQ result codes |
&A1 | Display ARQ result codes |
&A2 | Display ARQ result codes, HST, V.32, V.FC or V.34 modulation indicator |
&A3 | Display ARQ result codes and error control indicator LAPM, HST, MNP, SYNC, or NONE |
BREAK HANDLING | |
Type: | Configuration |
Format: | AT [cmds] &Yn [cmds] |
Description: | Controls the break handling |
Command | Function |
í &Y0 | Destructive, don’t send break |
&Y1 | Destructive, expedited break sent |
&Y2 | Nondestructive, expedited break sent |
&Y3 | Nondestructive un-expedited break sent |
CONNECTION RATE | |
Type: | Configuration |
Format: | AT [cmds] &Nn [cmds] |
Description: | Controls the connection rate |
Command | Function |
í &N0 | Variable rate |
&N1 | 300bps |
&N2 | 1200bps |
&N3 | 2400bps |
&N4 | 4800bps |
&N5 | 7200bps |
&N6 | 9600bps |
&N7 | 12Kbps |
&N8 | 14.4Kbps |
&N9 | 16.8Kbps |
&N10 | 19.2Kbps |
&N11 | 21.6Kbps |
&N12 | 24Kbps |
&N13 | 26.4Kbps |
&N14 | 28.8Kbps |
&N15 | 31.2Kbps |
&N16 | 33.6Kbps |
DATA COMPRESSION | |
Type: | Configuration |
Format: | AT [cmds] &Kn [cmds] |
Description: | Controls the data compression |
Command | Function |
&K0 | Data compression disabled |
í &K1 | Use auto enable/disable data compression |
&K2 | Data compression always enabled |
&K3 | Selective data compression |
DATA SET READY (DSR) | |
Type: | Configuration |
Format: | AT [cmds] &Sn [cmds] |
Description: | Selects DSR options |
Command | Function |
&S0 | DSR forced high |
í &S1 | DSR high only while modem is handshaking or connected |
&S2 | DSR and CTS follows CD when carrier is lost |
&S3 | DSR follows CD when carrier is lost |
&S4 | Send the computer a DSR signal at the same time as the CD |
&S5 | Send DSR normally, and follow CTS with CD |
DATA TERMINAL READY (DTR) | |
Type: | Configuration |
Format: | AT [cmds] &Dn [cmds] |
Description: | Selects modem response to DTR |
Note: The action each variant of &D causes depends on the setting of &Q | |
Command | Function |
í &D0 | Modem does not respond to DTR |
&D1 | Modem goes to command mode after DTR goes is off |
&D2 | Modem goes to command mode and disconnects (hangs up) after DTR goes off; Auto-Answer is disabled. |
DIAL | |
Type: | Immediate |
Format: | AT [cmds] D<#> [cmds] |
Description: | Dials telephone number according to any modifiers included in the string |
Note: | Any combination of modifiers can be used to produce the desired dial functions in sequence. |
Command | Function |
DL | Re-dial last number |
DP | Pulse dialing enabled |
DR | Reverse frequencies. |
DS=n | Dial stored telephone number n |
DT | Tone dialing enabled/Pulse dialing disabled |
DW | Dialing resumed following dial tone detection |
D, | Dialing paused for amount of time specified in S8 register |
D"WXY" | Optional method of denoting telephone numbers. Letters enclosed in quotes are interpreted as numbers according to the system found on a telephone keypad. |
D@ | Wait for Quite Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string. |
D$ | Wait for prompt tone detection function enabled. Waits for prompt tone for amount of time specified by the S7 command. |
D; | Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command. |
D" | Dial the letters that follow |
D/ | Pause for 125 milliseconds |
ERROR CONTROL | |
Type: | Configuration |
Format: | AT [cmds] &Mn [cmds] |
Description: | Selects the error control protocol |
Command | Mode |
í &M0 | Normal mode, no error control |
&M1 | Online synchronous mode |
&M4 | Normal/ARQ mode, |
&M5 | ARQ asynchronous mode |
&M6 | V.25bis synchronous mode. |
&M7 | V.25bis synchronous mode using HDLC link protocol |
FACTORY DEFAULT PROFILE | |
Type: | Configuration |
Format: | AT [cmds] &F [cmds] |
Description: | Sets values in active profile to values found in the default profile |
Command | Function |
í &F0 | Load No Flow Control template settings |
&F1 | Load Hardware Flow Control template settings |
&F2 | Load Software Flow Control template settings |
HARDWARE RESET | |
Type: | Immediate |
Format: | AT [cmds] Z! [cmds] |
Description: | If SW1/1 is on, then revert to the settings in NVRAM. If SW1/1 is off, reset to the &F0 configuration template |
HELP | |
Type: | Immediate |
Format: | AT [cmds] $ |
Description: | Display help screens for the AT basic command set |
HELP | |
Type: | Immediate |
Format: | AT [cmds] &$ |
Description: | Display help screens for the & command set |
HELP | |
Type: | Immediate |
Format: | AT [cmds] *$ |
Description: | Display help screens for the * command set |
HOOK CONTROL | |
Type: | Immediate |
Format: | AT [cmds] Hn [cmds] |
Description: | Selects whether the modem is on-hook or off-hook |
Command | Function |
í H0 | Modem commanded to go on-hook (hang-up) |
LINE TYPE | |
Type: | Configuration |
Format: | AT [cmds] &Ln [cmds] |
Description: | Selects line type |
Command | Line Type |
í &L0 | Switched line (PSTN/Dial-up) |
MODEM CLOCK | |
Type: | Configuration |
Format: | AT [cmds] Kn [cmds] |
Description: | Controls the modem clock |
Command | Function |
í K0 | If on-line, display current call duration; if off-line, display the last call’s duration |
K1 | Display the actual time (set clock using ATI3=HH:MM:SS K1) |
RECEIVE DATA FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] &In [cmds] |
Description: | Controls the receive data flow control |
Command | Jack Type |
í &I0 | Disables XON/XOFF flow control |
&I1 | Modem acts on typed XON/XOFF commands, Ctrl -S, or Ctrl -Q and passes them to remote device |
&I2 | Modem acts on typed XON/XOFF commands but removes them from data stream |
&I3 | Hewlett Packard host mode |
&I4 | Hewlett Packard terminal mode |
&I5 | Enable flow control on the phone link when the connection is not under error control |
REPEAT LAST ISSUED COMMAND | |
Type: | Immediate |
Format: | A> |
Description: | Repeats last issued command until any key is pressed |
Note: Do not precede this command with AT, or follow it with <CR>. | |
REPORT INFORMATION | |
Type: | Immediate |
Format: | AT [cmds] In [cmds] |
Description: | Displays information requested |
Command | Function |
I0 | Reports 4 digit product code |
I1 | Reports results of ROM checksum |
I2 | Reports results of RAM test |
I3 | Reports the product name |
I4 | Reports the current modem settings |
I5 | Reports the settings stored in NVRAM |
I6 | Reports statistics for the last call |
I7 | Reports product configuration |
I10 | Reports dial security account status information |
I11 | Displays high speed connection report |
I12 | Reports ISDN settings |
RESULT CODES | |
Type: | Configuration |
Format: | AT [cmds] Qn [cmds] |
Description: | Enables modem to send result codes to the DTE |
Command | Function |
í Q0 | Result code sending enabled |
Q1 | Result code sending disabled |
Q2 | Suppress result codes when answering |
RTS/CTS | |
Type: | Configuration |
Format: | AT [cmds] &Rn [cmds] |
Description: | Selects RTS/CTS options |
Command | Function |
í &R0 | CTS follows RTS in data mode; RTS is ignored in command mode. |
&R1 | CTS forced high, RTS is ignored. |
&R2 | Enable hardware flow control of received data |
SELECT CALL PROGRESS RESULT CODES | |
Type: | Configuration |
Format: | AT [cmds] Xn [cmds] |
Description: | Enables selection of tone detection and associated result code format options |
Command | Function |
X0 | Busy and dial tone detection disabled; result codes 0 - 4 enabled. |
X1 | Busy and dial tone detection disabled; result codes 0 - 5 & 10 enabled. |
X2 | Busy tone detection disabled, dial tone detection enabled; result codes 0 - 6 & 10 enabled. |
X3 | Busy tone detection enabled, dial tone detection disabled; result codes 0 - 5, 7 & 10 enabled. |
Í X4 | Busy and dial tone detection enabled; result codes 0 - 7 & 10 enabled. |
X5 | Busy tone detection enabled, dial tone detection disabled, all result codes enabled |
X6 | All result codes enabled |
X7 | Voice detection disabled, all result codes enabled |
SERIAL PORT RATE | |
Type: | Configuration |
Format: | AT [cmds] &Bn [cmds] |
Description: | Controls the serial port rate |
Command | Function |
í &B0 | Variable serial port rate |
&B1 | Fixed serial port rate |
&B2 | In answer mode use fixed rate for ARQ calls and variable rate for non ARQ calls. |
SOFTWARE RESET | |
Type: | Immediate |
Format: | AT [cmds] Z [cmds] |
Description: | If SW1/1 is set to on, revert to the settings in NVRAM. If SW1/1 is set to off, reset to the &F0 configuration template |
TEST MODES | |
Type: | Immediate |
Format: | AT [cmds] &Tn |
Description: | Selects test options |
Command | Function |
&T0 | End current test |
&T3 | Begin local digital loopback |
&T4 | Grant remote digital loopback request |
&T5 | Deny remote digital loopback request |
&T6 | Request remote digital loopback |
&T7 | Request remote digital loopback and self-test |
TRANSMIT DATA FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] &Hn [cmds] |
Description: | Controls the transmit data flow |
Command | Function |
í &H0 | Flow control disabled |
&H1 | Use hardware flow control enabled |
&H2 | Use software flow control enabled |
&H3 | Use both hardware and software flow control enabled |
Extended AT Commands
ASSIGN PASSWORD | |
Type: | Immediate |
Format: | AT [cmds] %V=PWn [cmds] |
Description: | Assign the password in account n in security account |
CALL TYPE | |
Type: | Configuration |
Format: | AT [cmds] *Vn [cmds] |
Description: | Set the call type for each B-channel |
Command | Function |
í *V0 | 0-5 for B-channel 1 |
*V1 | 0-5 for B-channel 2 |
DIRECTORY NUMBER | |
Type: | Configuration |
Format: | AT [cmds] *Pn [cmds] |
Description: | Set the directory number that was assigned to you by your telephone company |
Command | Function |
í *P1 | The DN for B-channel 1 |
*P2 | The DN for B-channel 2 |
ERASE SECURITY SETTINGS | |
Type: | Configuration |
Format: | AT [cmds] %En [cmds] |
Description: | Erases selected security settings |
Command | Function |
%E1 | Erase local access password |
%E2 | Erase autopass password |
%E3 | Erase passwords in accounts 0-9 |
%E4 | Erase phone numbers in accounts 0-9 |
%E5 | Disable account, dialback, and new number fields in accouns 0-9 |
LOCAL ACCESS PASSWORD | |
Type: | Configuration |
Format: | AT [cmds] %Ln [cmds] |
Description: | Set local access password |
PASSWORD SECURITY | |
Type: | Immediate |
Format: | AT [cmds] %P [cmds] |
Description: | Disable password security |
POINT TO POINT SELECTION | |
Type: | Configuration |
Format: | AT [cmds] *Mn [cmds] |
Description: | Select point to point or multipoint |
Command | Function |
í *M0 | Point to point |
*M1 | Multipoint |
REMOTE CONFIGURATION | |
Type: | Configuration |
Format: | AT [cmds] %Cn [cmds] |
Description: | Controls the remote configuration |
Command | Function |
%C0 | Defer configuration changes until the call is ended |
%C1 | Cancel configuration changes and restore the original configuration |
%C2 | Force configuration changes to take effect immediately |
REMOTE CONFIGURATION | |
Type: | Configuration |
Format: | AT [cmds] %Fn [cmds] |
Description: | Configure another device’s data remotely |
Command | Function |
%F0 | No parity, 8 data bits |
%F1 | Mark parity, 7 data bits |
%F2 | Odd parity, 7 data bits |
%F3 | Even parity, 7 data bits |
SECURITY ACCOUNTS | |
Type: | Configuration |
Format: | AT [cmds] %An [cmds] |
Description: | Create and configure security accounts |
SECURITY ACCOUNTS | |
Type: | Configuration |
Format: | AT [cmds] %Sn [cmds] |
Description: | Access security accounts |
SERIAL PORT RATE | |
Type: | Configuration |
Format: | AT [cmds] %Bn [cmds] |
Description: | Remotely configure a modem’s serial port rate |
Command | Function |
%B0 | 110bps |
%B1 | 300bps |
%B2 | 600bps |
%B3 | 1200bps |
%B4 | 2400bps |
%B5 | 4800bps |
%B6 | 9600bps |
%B7 | 19200bps |
%B8 | 38400bps |
%B9 | 57600bps |
%B10 | 115200bps |
SERVICE PROFILE ID | |
Type: | Configuration |
Format: | AT [cmds] *Sn [cmds] |
Description: | Set the service profile ID |
Command | Function |
í *S1 | the SPID for B-channel 1 |
*S2 | The SPID for B-channel 2 |
SWITCH PROTOCOL | |
Type: | Configuration |
Format: | AT [cmds] *Wn [cmds] |
Description: | Set the switch protocol used at the telephone company’s central office |
Command | Jack Type |
í *W0 | AT&T 5ESS Custom |
*W1 | Northern Telecom DMS-100 |
*W2 | National ISDN-1 |
*W3 | National ISDN-2 |
TERMINAL ENDPOINT ID | |
Type: | Configuration |
Format: | AT [cmds] *T [cmds] |
Description: | Sets the terminal endpoint (TEI) |
Command | Function |
í *T1 | 0-63 for B-channel 1 |
*T2 | 0-63 for B-channel 2 |
TONE FREQUENCIES | |
Type: | Configuration |
Format: | AT [cmds] %Tn [cmds] |
Description: | Enalbes recognition of the tone frequencies |
S(status) -REGISTERS
BIT MAPPED REGISTER | ||
Type: | Register | |
Format: | AT [cmds] S15=n [cmds] | |
Unit: | Bit-mapped | |
Description: | Controls fallback | |
Bit | Value | Function |
0 | 1 | Disable the modem’s extra high frequency equalization if it causes problems on shorter -link calls- for HST modulation only |
1 | 2 | Disable online fallback |
2 | 4 | Disable 450bps back channel ---HST only |
3 | 8 | Reset non-ARQ mode transmit buffer from 1.5Kbytes to 128 |
4 | 16 | Disable MNP level 4 |
5 | 32 | Set backspace key to delete |
6 | 64 | Alternate MNP setting for some 2400bps MNP modems not made by U.S. Robotics of Microcom. |
7 | 128 | Custom applications only |
BIT MAPPED REGISTER S16 | ||
Type: | Register | |
Format: | AT [cmds] S16=n [cmds] | |
Unit: | Bit-mapped | |
Description: | Controls loopback tests and test pattern | |
Bit | Value | Function |
2 | 4 | Test pattern |
3 | 8 | Remote digital loopback |
BIT MAPPED REGISTER S53 | |||
Type: | Register | ||
Format: | AT [cmds] S53=n [cmds] | ||
Description: | Bit mapped register | ||
Bit | Value | Function | |
0 | 1 | Dial security enabled | |
1 | 2 | Prompting enabled | |
2 | 4 | Local access password protection enabled | |
BIT MAPPED REGISTER S54 | |||
Type: | Register | ||
Format: | AT [cmds] S54=n [cmds] | ||
Description: | Bit mapped register | ||
Bit | Value | Function | |
0 | 1 | Disable 2400 symbol rate | |
1 | 2 | Disable 2743 symbol rate | |
2 | 4 | Disable 2800 symbol rate | |
3 | 8 | Disable 3000 symbol rate | |
4 | 16 | Disable 3200 symbol rate | |
5 | 32 | Disable 3429 symbol rate | |
6 | 64 | Disable Call Indicate | |
7 | 128 | Disable V.8 | |
BIT-MAPPED REGISTER S13 | ||
Format: | AT [cmds] S13=n [cmds] | |
Default: | 170 | |
Range: | 0-174 | |
Unit: | Bit-mapped | |
Description: | Controls echo, result codes and display, dial mode, and answer/originate mode. | |
Bit | Value | Function |
0 | 1 | Reset when DTR drops |
1 | 2 | Reverse normal auto answer mode |
2 | 4 | Disable 250 msec pause before result code display |
3 | 8 | On DTR signal, Autodial the number stored in NVRAM at position 0 |
4 | 16 | At power on/reset, auto dial number stored in NVRAM at position 0 |
5 | 32 | Disable HST |
6 | 64 | Disable MNP level 3 |
7 | 128 | Hardware reset |
BIT-MAPPED REGISTER S14 | ||
Format: | AT [cmds] S14=n [cmds] | |
Default: | 170 | |
Range: | 0-174 | |
Unit: | Bit-mapped | |
Description: | Controls echo, result codes and display, dial mode, and answer/originate mode. | |
Bit | Value | Function |
0 | í 1 | Disconnect on escape code |
1 | 2 | Send result codes only when originating a call |
BIT-MAPPED REGISTER S28 | |
Format | AT [cmds] S28=n [cmds] |
Default: | Unidentified |
Range: | 8 |
Unit: | .1 second |
Description: | Sets the duration of the extra 3000/600 Hz answer tones sent during handshaking. |
BITMAPPED REGISTER S27 | ||
Format | AT [cmds] S27=n [cmds] | |
Default: | Unidentified | |
Range: | 0 | |
Unit: | Bit-mapped | |
Description: | Selects modulation | |
Bit | Value | Function |
0 | 1 | Enable ITU-T V.21 |
1 | 2 | Enable unencoded modulation in V.32 mode |
2 | 4 | Disable V.32 modulation |
3 | 8 | Disabl;e 2100Hz answer tone |
4 | 0 16 0 16 | Complete handshaking sequence:V.42 detection, LAPM error control, MNP Disable MNP Disable V.42 detection and LAPM Disable detection phase |
5 | 0 0 32 32 | Complete handshaking sequence:V.42 detection, LAPM error control, MNP Disable MNP Disable V.42 detection and LAPM Disable detection phase |
7 | 128 | Unusual software incompatibility |
BITMAPPED REGISTER S29 | |
Type: | Register |
Format | AT [cmds] S29=n [cmds] |
Default: | 20 |
Range: | Unidentified |
Unit: | .1 sec |
Description: | Sets the duration of the V.21 answer tone |
BIT-MAPPED REGISTER S34 | ||
Type: | Register | |
Format: | AT [cmds] S34n [cmds] | |
Default: | 0 | |
Range: | Unidentified | |
Unit: | Unidentified | |
Description: | Controls V.32bis | |
Bit | Value | Function |
0 | 1 | Disable V.32bis |
1 | 2 | Disable modem’s enhanced proprietary V.32bis modulation |
2 | 4 | Disable the faster retrains that occure during proprietary V.32terbo modulation |
3 | 8 | Enable V.23 |
4 | 16 | Force the MR LED to show DSR |
5 | 32 | Enable MI/MIC |
6 | 64 | Disable the remote access busy message |
7 | 128 | Disable V.32terbo |
BIT-MAPPED REGISTER S51 | ||
Format | AT [cmds] S51=n [cmds] | |
Default: | 0 | |
Range: | Unidentified | |
Unit: | Bit-mapped | |
Description: | MNP/V.42 control | |
Bit | Value | Function |
0 | 1 | Disable MNP/V.42 for V.22 |
1 | 2 | Disable MNP/V.42 for V.22bis |
2 | 4 | Disable MNP/V.42 for V.32/V.32bis/V.32terbo |
6 | 64 | Disable selective reject |
7 | 128 | Enable handset exclusion delay |
BIT-MAPPED REGISTER S55 | ||
Type: | Register | |
Format | AT [cmds] S55=n [cmds] | |
Description: | Bit-mapped register | |
Bit | Value | Function |
0 | 1 | Disable 8S-2D mapping |
1 | 2 | Disable 16S-4D mapping |
2 | 4 | Disable 32S-2D mapping |
3 | 8 | Disable 64S-4D mapping |
7 | 128 | Enable phase roll detection |
BIT-MAPPED REGISTER S56 | ||
Type: | Register | |
Format | AT [cmds] S56 [cmds] | |
Description: | Bit-mapped register | |
Bit | Value | Function |
0 | 1 | Disable non-linear coding |
1 | 2 | Disable TX level deviation |
2 | 4 | Disable pre-emphasis |
3 | 8 | Disable precoding |
4 | 16 | Disable shaping |
5 | 32 | Disable 31.2 and 33.6 speeds in V.34 |
6 | 64 | Disable V.34 |
7 | 128 | Disable V.FC |
BIT-MAPPED REGISTER S69 | ||
Type: | Register | |
Format: | AT [cmds] S69=n [cmds] | |
Description: | Bit-mapped register | |
Bit | Value | Function |
0 | 1 | Disable plug and play signaling |
1 | 2 | Enable carrier loss redial |
BIT-MAPPED REGISTER S70 | ||
Type | Register or Configuration | |
Format | AT [cmds] S70=n [cmds] | |
Description | Bit-mapped register | |
Bit | Value | Function |
0 | 1 | Enable recognition of Ring A |
1 | 2 | Enable recognition of Ring B |
2 | 4 | Enable recognition of Ring C |
3 | 8 | Enable recognition of Ring D |
BREAK LENGTH | |
Format | AT [cmds] S21=n [cmds] |
Default: | Unidentified |
Range: | Unidentified |
Unit: | 10msec |
Description: | Sets the duration of breaks sent from the modem to the computer or terminal |
DSR RECOGNITION | |
Type: | Register |
Format | AT [cmds] S25=n [cmds] |
Default: | 5 |
Range: | Unidentified |
Unit: | .1 second |
Description: | Sets DTR recognition time |
DSR SIGNAL | |
Type: | Register |
Format | AT [cmds] S24=n [cmds] |
Default: | 150 |
Range: | Unidentified |
Unit: | .02 sec |
Description: | Sets the duration between pulsed DSR signals when the modem is set to &S2 or &S3. |
FLOW CONTROL CHARACTER - XOFF | |
Format | AT [cmds] S23=n [cmds] |
Default: | 19 |
Range: | Unidentified |
Description: | Stores the ASCII code for the XOFF character |
GUARD TIME DURATION | |
Type: | Register |
Format | AT [cmds] S43=n [cmds] |
Default: | 200 |
Unit: | .02 sec |
Description: | Sets the duration of the guard time for the remote access sequence |
INACTIVITY TIMER | |
Type: | Register |
Format | AT [cmds] S19=n [cmds] |
Default: | Unidentified |
Range: | Unidentified |
Unit: | Minute |
Description: | Sets the duration in minutes for the inactivity timer, S19=0 disables the timer |
REESTABLISHING CONNECTION INTERVAL | |
Format | AT [cmds] S44=n [cmds] |
Default: | 15 |
Description: | Sets the duration of the interval between losing carrier and reestablishing a connection |
REMOTE ACCESS | |
Type: | Register |
Format | AT [cmds] S41=n [cmds] |
Description: | Sets the number of allowable remote access login attempts, thus enabling or disabling remote access. |
REMOTE ACCESS ESCAPE CHARACTER | |
Type: | Register |
Format | AT [cmds] S42=n [cmds] |
Default: | 126 |
Range: | Unidentified |
Unit: | Unidentified |
Description: | Stores the ASCII decimal code for the remote access escape character. |
TRANSMIT BUFFER | |
Type: | Register |
Format | AT [cmds] S38n [cmds] |
Description: | Sets the time before a forced hang up and clearing of the transmit buffer when DTR drops during an ARQ call. |
VOICE/DATA SWITCH | |
Type: | Register |
Format | AT [cmds] S32=n [cmds] |
Default: | 9 |
Range: | Unidentified |
Unit: | Unidentified |
Description: | Assign voice/data switch function |
Value | Function |
0 | Disabled |
1 | Voice/data - originate mode |
2 | Voice/data - answer mode |
3 | Radial last number |
4 | Dial number stored at position 0 |
5 | Auto answer on/off toggle |
6 | Reset modem |
7 | Initiate remote digital loopback |
8 | Busy out the phone line toggle |
9 | Execute stored command |
XON CHARACTER | |
Format | AT [cmds] S22=n [cmds] |
Default: | 17 |
Range: | Unidentified |
Unit: | Bit-mapped |
Description: | Stores the ASCII code for XON character |