3COM CORPORATION
IMPACT (3C870, 3C875)
Card Type | ISDN TA |
Chipset | Unidentified |
Error Correction/Compression | STAC |
ISDN Transfer Rate | 56Kbps x 2/64Kbps x 2 |
ISDN Protocol | V.120, PPP |
Switch Type | 5ESS, DMS100, EWSD, NI-1 |
Data Bus | Serial |

CONNECTIONS | ||||||
Function | Label | Function | Label | |||
ISDN interface | CN1 | DC power in | CN4 | |||
Serial port | CN2 | Power switch | SW1 | |||
Analog adapter | CN3 | |||||
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
B2 | Green | On | Data call connected on B2 channel |
B2 | Yellow | On | Voice call connected on B2 channel |
B2 | Green | Blinking | TA is dialing data call on B2 channel |
B2 | Yellow | Blinking | TA is dialing voice call on B2 channel |
B2 | N/A | Off | B2 channel is not connected |
B1 | Green | On | Data call connected on B1 channel |
B1 | Yellow | On | Voice call connected on B1 channel |
B1 | Green | Blinking | TA is dialing data call on B1 channel |
B1 | Yellow | Blinking | TA is dialing voice call on B1 channel |
B1 | N/A | Off | B1 channel is not connected |
DIAGNOSTIC LED(S) (CON'T) | |||
LED | Color | Status | Condition |
D | Yellow | On | Signal is not synchronized or ISDN line is not connected |
D | Yellow | Blinking | Signal is synchronized but D-channel protocols not established |
D | Yellow | Off | Signal is synchronized |
TEST | Yellow | On | TA failed last test |
TEST | Yellow | Blinking | TA is executing test |
TEST | Yellow | Off | TA is not executing test |
POWER | Yellow | On | Power is on |
POWER | Yellow | Off | Power is off |
SUPPORTED STANDARD COMMANDS |
Basic AT Commands |
+++, A/ |
A, D, E, H, O, V, Z |
&D, &F, &W |
Extended AT Commands |
\Q, \T |
S-Registers |
S0 |
Note: See MHI help file for complete information. |
UNIDENTIFIED COMMANDS | |
Command | Default |
S63 | Unidentified |
S64 | Unidentified |
Proprietary AT Command Set
CALL TYPE | |
Type: | Register |
Format: | AT [cmds] S61=n [cmds] |
Description: | Selects the type of call the TA will make. |
Command | Function |
í S61=0 | TA will dial according to dial modifiers. |
S61=1 | TA will place Switched 56 call. |
S61=2 | TA will place ISDN call. |
S61=3 | TA will place modem call. |
S61=4 | TA will place voice call. |
S61=5 | TA will use third-party call control. |
See 3COM CORPORATION IMPACT (3C871) for a full command summary.