RESEARCH IN MOTION LIMITED
MX25
Card Type | X.25 PAD |
Chip Set | Unidentified |
I/O Options | Printer/diagnostic port |
Transfer Rate | 19.2Kbps |
Data Bus | External |
CONNECTIONS | |||
Function | Label | Function | Label |
RS-232 X.25 to DTE | CN1 | Diagnostic/printer port | CN3 |
RS-232 to X.25 network transmission device | CN2 | DC power | CN4 |
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
» | Hardware flow control is not being used | J401 | Open |
Hardware flow control is being used | J401 | Closed | |
» | Factory configured - do not alter | J201 | Open |
» | Factory configured - do not alter | J402 | Open |
» | Factory configured - do not alter | J403 | Open |
» | Factory configured - do not alter | J404 | Open |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
ERR | Red | On | A fatal error has occurred (after initial start-up) |
ERR | Red | Off | A fatal error has not occurred |
RX1 | Red | On | PAD is receiving data from DTE |
RX1 | Red | Off | PAD is not receiving data from DTE |
TX1 | Red | On | PAD is transmitting data to DTE |
TX1 | Red | Off | PAD is not transmitting data to DTE |
HP | Red | On | PAD is waiting for an incoming call |
HP | Red | Off | PAD is busy and not waiting for an incoming call |
COMP | Red | On | X.25 link to network is good |
COMP | Red | Off | X.25 link to network is not good |
RX2 | Red | On | PAD is receiving data from network |
RX2 | Red | Off | PAD is not receiving data from network |
TX2 | Red | On | PAD is transmitting data to network |
TX2 | Red | Off | PAD is not transmitting data to network |
CONT | Red | On | X.25 call has connected |
CONT | Red | Off | No X.25 call has connected |
PWR | Red | On | Power is on |
PWR | Red | Off | Power is off |
Note:LEDs will blink during self-test sequence. |