RAD DATA COMMUNICATIONS
CMN-CEB
Card Type | Elastic buffer |
Chipset | Unidentified |
I/O Options | Serial port |
Maximum Data Rate | 64Kbps |
Data Bus | Serial |
CONNECTIONS | |
Function | Label |
Serial ports via DB-25 cable | CN1 |
Note:Two standard DB-25 serial ports are provided on an included adapter cable. |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
PWR | Green | On | Power is on |
PWR | Green | Off | Power is off |
XMT1 | Yellow | On | Port 1 is transmitting data |
XMT1 | Yellow | Off | Port is 1 not transmitting data |
RCV1 | Yellow | On | Port 1 is receiving data |
RCV1 | Yellow | Off | Port 1 is not receiving data |
XMT2 | Yellow | On | Port 2 is transmitting data |
XMT2 | Yellow | Off | Port is 2 not transmitting data |
RCV2 | Yellow | On | Port 2 is receiving data |
RCV2 | Yellow | Off | Port 2 is not receiving data |
MISCELLANEOUS TECHNICAL NOTE |
This card is intended for use in the CMN-16 rack-mount system. The bus is used only for supplying power for the card. All other card functions are accessed through the serial port. |