ARNET CORPORATION
MULTIPORT
Card Type | I/O controller |
Chipset/Controller | Startech UART |
I/O Options | Serial port (4 or 8) |
Maximum DRAM | N/A |
CONNECTIONS | |
Purpose | Location |
DB-62 connector | CN1 |
UART I/O ADDRESS CONFIGURATION | |||||
Address | SW1/1 | SW1/2 | SW1/3 | SW1/4 | SW1/5 |
100h | On | On | On | Off | On |
140h | On | Off | On | Off | On |
180h | On | On | Off | Off | On |
1C0h | On | Off | Off | Off | On |
200h | On | On | On | On | Off |
240h | On | Off | On | On | Off |
300h | On | On | On | Off | Off |
340h | On | Off | On | Off | Off |
280h | On | On | Off | On | Off |
2C0h | On | Off | Off | On | Off |
380h | On | On | Off | Off | Off |
3C0h | On | Off | Off | Off | Off |
OPTION I/O ADDRESS CONFIGURATION | |||||||
Address | SW2/1 | SW2/2 | SW2/3 | SW2/4 | SW2/5 | SW2/6 | SW2/7 |
100h | On | On | On | On | On | Off | On |
110h | On | Off | On | On | On | Off | On |
120h | On | On | Off | On | On | Off | On |
130h | On | Off | Off | On | On | Off | On |
140h | On | On | On | Off | On | Off | On |
150h | On | Off | On | Off | On | Off | On |
160h | On | On | Off | Off | On | Off | On |
170h | On | Off | Off | Off | On | Off | On |
180h | On | On | On | On | Off | Off | On |
190h | On | Off | On | On | Off | Off | On |
1A0h | On | On | Off | On | Off | Off | On |
1B0h | On | Off | Off | On | Off | Off | On |
1C0h | On | On | On | Off | Off | Off | On |
1D0h | On | Off | On | Off | Off | Off | On |
1E0h | On | On | Off | Off | Off | Off | On |
1F0h | On | Off | Off | Off | Off | Off | On |
200h | On | On | On | On | On | On | Off |
210h | On | Off | On | On | On | On | Off |
220h | On | On | Off | On | On | On | Off |
230h | On | Off | Off | On | On | On | Off |
240h | On | On | On | Off | On | On | Off |
250h | On | Off | On | Off | On | On | Off |
260h | On | On | Off | Off | On | On | Off |
270h | On | Off | Off | Off | On | On | Off |
280h | On | On | On | On | Off | On | Off |
290h | On | Off | On | On | Off | On | Off |
2A0h | On | On | Off | On | Off | On | Off |
2B0h | On | Off | Off | On | Off | On | Off |
2C0h | On | On | On | Off | Off | On | Off |
2D0h | On | Off | On | Off | Off | On | Off |
2E0h | On | On | Off | Off | Off | On | Off |
2F0h | On | Off | Off | Off | Off | On | Off |
300h | On | On | On | On | On | Off | Off |
310h | On | Off | On | On | On | Off | Off |
320h | On | On | Off | On | On | Off | Off |
330h | On | Off | Off | On | On | Off | Off |
340h | On | On | On | Off | On | Off | Off |
350h | On | Off | On | Off | On | Off | Off |
360h | On | On | Off | Off | On | Off | Off |
370h | On | Off | Off | Off | On | Off | Off |
380h | On | On | On | On | Off | Off | Off |
OPTION I/O ADDRESS CONFIGURATION (CONTINUED) | |||||||
Address | SW2/1 | SW2/2 | SW2/3 | SW2/4 | SW2/5 | SW2/6 | SW2/7 |
390h | On | Off | On | On | Off | Off | Off |
3A0h | On | On | Off | On | Off | Off | Off |
3B0h | On | Off | Off | On | Off | Off | Off |
3C0h | On | On | On | Off | Off | Off | Off |
3D0h | On | Off | On | Off | Off | Off | Off |
3E0h | On | On | Off | Off | Off | Off | Off |
3F0h | On | Off | Off | Off | Off | Off | Off |
INTERRUPT SELECT | ||||||
IRQ | SW3/1 | SW3/2 | SW3/3 | SW3/4 | SW3/5 | SW3/6 |
IRQ2 | On | Off | Off | Off | Off | Off |
IRQ3 | Off | On | Off | Off | Off | Off |
IRQ4 | Off | Off | On | Off | Off | Off |
IRQ5 | Off | Off | Off | On | Off | Off |
IRQ6 | Off | Off | Off | Off | On | Off |
IRQ7 | Off | Off | Off | Off | Off | On |
Not used | Off | Off | Off | Off | Off | Off |
RECOMMENDED OPERATING SYSTEM CONFIGURATIONS | ||||
Operating System | Address Setting | UART I/O Address | Option I/O Address | IRQ |
Concurrent DOS | Primary | 280h | 270h | IRQ3 |
Concurrent DOS | Alternate | 2C0h | 2B0h | IRQ3 |
Formula IV | Primary | 280h | Not used | IRQ2 |
Formula IV | Alternate | Any unused area | Not used | Not used |
SunSoft Interactive 386/ix | Primary | 200h | 240h | IRQ3 |
SunSoft Interactive 386/ix | Alternate | 280h | 2C0h | IRQ3 |
MBOS/5, BOS/LAN | Primary | 2C0h | Not used | IRQ3 |
MBOS/5, BOS/LAN | Alternate | 100h | Not used | IRQ3 |
MBOS/5, BOS/LAN | Alternate | 200h | Not used | IRQ3 |
Microport UNIX | Primary | 100h | Not used | IRQ3 |
Microport UNIX | Alternate | 280h | Not used | IRQ3 |
Micronetic MUMPS | Primary | 280h | Not used | IRQ3 |
Micronetic MUMPS | Alternate | 240h | Not used | IRQ5 |
MUMPS/CCSM MUMPS | Primary | 280h | 2C0h | IRQ3 |
MUMPS/CCSM MUMPS | Alternate | 200h | 2D0h | IRQ3 |
PC-MOS/386 | Primary | 280h | Not used | IRQ2 |
PC-MOS/386 | Alternate | 100h | Not used | IRQ2 |
RECOMMENDED OPERATING SYSTEM CONFIGURATIONS (CONTINUED) | ||||
Operating System | Address Setting | UART I/O Address | Option I/O Address | IRQ |
PICK | Primary | 280h | 2C0h | IRQ4 |
PICK | Alternate | 180h | 1C0h | IRQ3 |
PICK OA | Primary | 200h | 240h | IRQ2 |
PICK OA | Alternate | 100h | 140h | IRQ7 |
QNX | Primary | 280h | Not used | IRQ2 |
QNX | Primary | 280h | Not used | IRQ3 |
QNX | Primary | 280h | Not used | IRQ4 |
QNX | Primary | 280h | Not used | IRQ5 |
Quick Connect | Primary | 280h | Not used | IRQ4 |
SCO XENIX/UNIX V | Primary | 100h | 140h | IRQ4 |
SCO XENIX/UNIX V | Alternate | 280h | 2C0h | IRQ4 |
SCO XENIX/UNIX V | Primary | 180h | 1C0h | IRQ3 |
SCO XENIX/UNIX V | Alternate | 300h | 340h | N/A |
THEOS | Primary | 100h | 140h | IRQ5 |
THEOS | Alternate | 180h | 1C0h | IRQ7 |
VENIX/86 | Primary | 280h | Not used | IRQ3 |
VENIX/86 | Alternate | 280h | Not used | IRQ4 |
VM/386 | Primary | 300h | 340h | IRQ5 |
XMM-DOS | Primary | 100h | 180h | IRQ2 |
XMM-DOS | Alternate | 140h | 190h | IRQ7 |
MS-DOS | Primary | 280h | Not used | IRQ2 |
MS-DOS | Alternate | 140h | Not used | IRQ3 |