S T 4 1 5 2 0 N D S W I F T SEAGATE
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 5.25"/FH Cylinders 2098| | |
Capacity form/unform 1370/ 1600 MB Heads 17| | |
Seek time / track 11.5/ 1.7 ms Sector/track | | |
Controller SCSI2 DIFFERENTIAL Precompensation
Cache/Buffer 256 KB ADAPTIVE Landing Zone
Data transfer rate 3.000 MB/S int Bytes/Sector 512
5.000 MB/S ext
Recording method RLL 2/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C |
Power: sleep W Humidity % |
standby W Altitude km |
idle W Shock g |
seek 33.1 W Rotation RPM 5400
read/write W Acoustic dBA
spin-up W ECC Bit
MTBF h 150000
Warranty Month
Lift/Lock/Park YES Certificates
SEAGATE ST41520N/ND JUMPER SETTING
Jumper Setting
==============
I/O BOARD +-------Parity Disable
| +-Spinup Delay (10s)
| | +----- Manual Reset
| | | + Active LED(red)
+-- Spindle Sync | | | | +Heartbeat LED
A| SCSI ID --+ ++-+-++| | (green)
1o-o+ +-------------------------+ | |o o o|* *
+--+p n+--+XXXXXXXXXXXXXXXXXXXXXXXX1+--+--+--+o o o+----------------+
| |o o| +-------------------------+ |o o o+-----+ o|
| +o-o+ +----------1 +----------1 |o o o| o
| o-o5 +---|------+ +---|------+ +4-2-1+ |
|B + T-RES +-----++ T-RES ONLY on Motor Start --+
| |3o o4| Differential Enable
+-- Select |2o o1|
Plug +--+--+
| DC Power Connector J15
| 0-0-0-0-0-0-0-0-0-1
|
+------------------------+---------+
| Terminator Power Source Options |
+----------------------------------+--------------------------------+
|2 & 3 - Host supplies power over the SCSI Bus for terminators. |
| Drive supplies no terminator power. |
|1 & 2 - Drive supplies power for its own terminator resistor-paks |
| but not to SCSI Bus. This is the factory setting. |
| 4 - Not used. |
+-------------------------------------------------------------------+
Servo Board
Fault LED (red) ------+
Ready LED (green) ---+ | DIP SWITCHES
Unit Selected(amber) + | | S3 S2 S1
| | | +--------++--------++--------+On
* * * |12345678||12345678||12345678|
+--------++--------++--------+Off
+--------+------+| ||||+-++
| | |||| |
Sector Switches (all OFF) --+ | |||| |
Runt Sector -8--------+ |||| |
Sweep Cycle Enable -1-----------+||| |
Enable Sweep only on seeks -2------------+|| |
Manufacturing Test (keep OFF) -3-------------+| |
Write Enable (default ON) -4--------------+ |
Unit Select Switches (all OFF) -6-8---------------+