F I R E B A L L S E 6 4 0 0 A T QUANTUM
Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders |13328| |
Capacity form/unform 6400/ MB Heads | 15| |
Seek time / track 9.5/ ms Sector/track | 63| |
Controller IDE / ATA3 ULTRA Precompensation
Cache/Buffer 128 KB Landing Zone
Data transfer rate 19.750 MB/S int Bytes/Sector 512
33.300 MB/S ext UDMA
Recording method EPRML operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 55 |
Power: sleep W Humidity % 5 85 |
standby W Altitude km -0.200 3.000|
idle W Shock g 10 |
seek W Rotation RPM 5400
read/write W Acoustic dBA 32
spin-up W ECC Bit 224BIT,SMART
MTBF h 500000
Warranty Month 36
Lift/Lock/Park YES Certificates
QUANTUM FIREBALL SE AT
ATA CABLE PIN+ Not Used
+--------------------------------------1----------++--------+
|* * * * * * * * * * * * * * * * * * * * * * * * *| XXXXXX |
|* * * * * * * * * * * * * * * * * * * * * * *| xxxxxx |
+--------------------+----------------------+-+-+--+-Power--+
Blank key DS+ | PK
CS
QUANTUM FIREBALL SE AT
Jumper Setting
==============
Master/Slave Setting -------------------- +----+----+----+----+ |DS |CS |PK |RSVD| +----+----+----+----+----------------+ |ON |OFF |OFF |OFF | STAND ALONE | +----+----+----+----+----------------+ |ON |OFF |OFF |OFF | MASTER TO SLAVE| +----+----+----+----+----------------+ |OFF |OFF |OFF |OFF | SLAVE TO MASTER| +----+----+----+----+----------------+
-ANY DIREC.
Notes on installation
=====================
Installation direction
----------------------
horizontally vertically
+-----------------+ +--+ +--+
| | | +-----+ +-----+ |
| | | | | | | |
+-+-----------------+-+ | | | | | |
+---------------------+ | | | | | |
| | | | | |
| | | | | |
+---------------------+ | +-----+ +-----+ |
+-+-----------------+-+ +--+ +--+
| |
| |
+-----------------+
The drive will operate in all axis (6 directions).