1 3 0 4    MICROPOLIS
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 5.25"/FH              Cylinders     830|     |     |
Capacity form/unform    42/      MB        Heads           6|     |     |
Seek time   / track  30.0/ 6.0 ms          Sector/track   17|     |     |
Controller           MFM / ST412           Precompensation 65535
Cache/Buffer               KB              Landing Zone      829
Data transfer rate    0.625 MB/S int       Bytes/Sector      512
                      0.625 MB/S ext
Recording method     MFM                            operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C                 |
Power: sleep              W     Humidity     %                 |
       standby            W     Altitude    km                 |
       idle               W     Shock        g                 |
       seek               W     Rotation   RPM      3600
       read/write         W     Acoustic   dBA
       spin-up            W     ECC        Bit
                                MTBF         h      20000
                                Warranty Month
Lift/Lock/Park     YES          Certificates                                  

Layout

MICROPL. 1320 SERIES PRODUCT DESCRIPTION 101400 REV. B-3

  +---------------------------------------------------------+
  |                                                         |
  |                                      Interface   +--+   |X1 J1
  |  COMPONENT SIDE                      Terminator  |  |RN1|XX
  |                                                  |  |   |XX
  |                                                  +--+   |XX
  |                                                         |XX
  |                                                         |XX
  |                                               W1 +-+    |XX
  |                                               W2 | |    |
  |                                               DS1| |    |X1
  |                                               DS2| |    |XX J2
  |                                               DS3| |    |XX
  |                                               DS4| |    |XX
  |                                                  +-+    |XX
  |                                                         |XX
  |                                                         |
  |                                                         |
  +---------------------------------------------------------+

     +--------------------------------------+
     |       ++J4                           |
     |       ++                             |
     |          ++J5                        |
     |  J3 Power++                          |
     |  XXXXXX1                             |
     |      J2             J1               |
     |  XXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXX  |
     +--------------1--------------------1--+
      Data Transfer    Control Signal

Jumpers

MICROPL. 1300 SERIES JUMPER SETTING

Jumper Setting
==============

                   J1                  J2       Power
  +----+ +------------------+   +------------+ +--------+
  |    | |1                 |   |1           | | X X    |
  |    +-+                  +---+            +-+W7 W8   |
  |                  W2 Drive Select                    |
  |   xxxxxxxxxx   X X X X X X                          |
  |   RN1         W1   1 2 3 4                          |
  |                                                     |
  |                                                     |
  |                 (COMPONENT SIDE)                    |

Drive Select Jumpers
--------------------
Only one Drive Select jumper is installed on a drive. For every
drive in a PC/AT installation, move the jumper from DS1 to DS2 (the
special twisted interface cable that is generally used, takes care of
assigning a unique address to each drive). Some other systems may
require that each drive be jumpered to a unique address.

The drives are shipped with the jumper installed at DS1.

    +------+---------------------------+
    |      |           Pins            |
    |Drive | 1    |2     |3     |4     |
    +------+------+------+------+------+
    |  1   |CLOSED|OPEN  |OPEN  |OPEN  |
    +------+------+------+------+------+
    |  2   |OPEN  |CLOSED|OPEN  |OPEN  |
    +------+------+------+------+------+
    |  3   |OPEN  |OPEN  |CLOSED|OPEN  |
    +------+------+------+------+------+
    |  4   |OPEN  |OPEN  |OPEN  |CLOSED|
    +------+------+------+------+------+

W1 Write Fault Latch
--------------------
W1 is the Write Fault Latch. If W1 is present and the drive
encounters a write fault, all writing to the drive is inhibited
until after the drive has been deselected. If W1 is absent, fault
conditions are not latched. Drives are shipped with a jumper
installed at W1; remove it for PC/AT installations.

W2 and W8 are always installed.

W7 Never install.

RN1 Interface Terminator
------------------------
The Interface Terminator factory installed at RN1 provides proper
termination for the interface lines. When daisy-chaining multiple
1300 drives, leave the terminator in the last physical drive on
the daisy chain cable; remove the terminator from each of the
other drives. In most PC/AT installations, the C: drive is actually
at the end of the cable and should retain the terminator.

Install

-ANY DIREC.

Notes on installation
=====================

Installation direction
----------------------

     horizontally                           vertically
   +-----------------+             +--+                       +--+
   |                 |             |  +-----+           +-----+  |
   |                 |             |  |     |           |     |  |
 +-+-----------------+-+           |  |     |           |     |  |
 +---------------------+           |  |     |           |     |  |
                                   |  |     |           |     |  |
                                   |  |     |           |     |  |
 +---------------------+           |  +-----+           +-----+  |
 +-+-----------------+-+           +--+                       +--+
   |                 |
   |                 |
   +-----------------+

The drive will operate in all axis (6 directions).

Features

MICROPL. 1300 SERIES PRODUCT DESCRIPTION

PC Drive Types
--------------
Examine the entries in your drive table and find the type that most
resembles the head and cylinder parameters of the drive without
exceeding the drive parameters. If you are using third-party
installation/partitioning software, follow the instructions included
with the software as it may perform this step automatically.

 Performance Specifications
 --------------------------
 Seek Time (including settling time)     Track-to-Track   6 msec
                                         Average         30 msec
                                         Maximum         60 msec

 Average Rotational Latency                            8.33 msec
 Rotational Speed                              3600 rpm +/- 0.5%
 Data Transfer Rate                                  5 Mbits/sec
 Optimum Step Rate             20 usec or faster (buffered seek)
 MTBF                                               20,000 hours
 Positioner                     Fully balanced rotary voice coil
 Parking                                 Automatic park and lock

General Functional Specifications
---------------------------------
Encoding Method: MFM (Modified Frequency Modulation)
(Although these drives may be capable of functioning in an RLL
environment, Micropolis does not certify or warrant them for this
application.)

Sectoring Soft
Write Precompensation Start Cylinder 830*
Reduced Write Current Start Cylinder 830*
Landing Zone 830
Type of Media Plated
Mounting Plane Any orientation