8 5 1 2 1 A 8 O E M D I A M O N D MAXTOR
Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 6569|10585| |
Capacity form/unform 5121/ MB Heads 8| 15| |
Seek time / track 10.0/ 1.0 ms Sector/track | 63| |
Controller IDE / ATA3 Precompensation
Cache/Buffer 256 KB MAXCACHE Landing Zone
Data transfer rate 8.000 MB/S int Bytes/Sector 512
16.700 MB/S ext PIO4
Recording method RLL 8/9 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 55 | -40 71
Power: sleep 0.6 W Humidity % 5 95 | 5 95
standby 0.8 W Altitude km -0.061 3.048|
idle 4.5 W Shock g 20 | 150
seek 5.0 W Rotation RPM 5400
read/write 5.3 W Acoustic dBA 36
spin-up 12.4 W ECC Bit SMART
MTBF h 500000
Warranty Month
Lift/Lock/Park YES Certificates
MAXTOR 85121A8 JUMPER SETTING
J1 IDE Connector Jumper J2 Power
+----------- ----------++-----------++---------+
| .................... || * * * * || X X X X |
| .......... ......... || * * * * * || X X X X |
+----------------------++-----------++---------+
MAXTOR 85121A8 JUMPER SETTING
Jumper Setting
==============
+---+---+---+---+---+
Jumper Destination |J50|J48|J46|J44|J42|
+-------------------------------------+---+---+---+---+---+
| Master/Slave | | | | | |
| Only Drive in single drive system* | J | | | | |
| Master in a dual drive system* | J | | | | |
| Slave in a dual drive system | O | | | | |
+-------------------------------------+---+---+---+---+---+
| Cable Select | | | | | |
| Disabled* | | O | | | |
| Enabled | | J | | | |
+-------------------------------------+---+---+---+---+---+
| 4092 Cylinder Option | | | | | |
| Disabled* | | | O | | |
| Enabled | | | J | | |
+-------------------------------------+---+---+---+---+---+
| Factory Reserved | | | | O | |
+-------------------------------------+---+---+---+---+---+
| Factory Reserved | | | | | O |
+-------------------------------------+---+---+---+---+---+
J=Jumpered O=Open *=Default
Pin 1
J1 IDE Connector | J2 Power
+----------- --------|-++-----------+----------+
| .................... || @ * * o |/ \
| .......... ......... || @ o o o o || O O O O |
+----------------------++-----------++---------+
| | | | | | | | |
| | | | | | | | |
J50 Master/Slave -----+ | | | | | | | + +12V (Yellow)
J48 Cable Select -------+ | | | | | +-- +12V Return (Black)
J46 4092 Cyl Limitation---+ | | | +----- +5V Return (Black)
J44 Factory Reserved -------+ | +------- +5V (Red)
J42 Factory Reserved ---------+
@ = Default Jumped Positions
* = "Spare" Jumper Position
o = Default Open Positions
-ANY DIREC.
Notes on installation
=====================
Installation direction
----------------------
horizontally vertically
+-----------------+ +--+ +--+
| | | +-----+ +-----+ |
| | | | | | | |
+-+-----------------+-+ | | | | | |
+---------------------+ | | | | | |
| | | | | |
| | | | | |
+---------------------+ | +-----+ +-----+ |
+-+-----------------+-+ +--+ +--+
| |
| |
+-----------------+
The drive will operate in all axis (6 directions).
MAXTOR 85121A8 JUMPER SETTING
Power Mode Definitions:
-----------------------
Active
The drive is spinning and most circuitry is powered on. The drive is
capable of responding to read commands in the shortest possible
time. Read/Write heads are positioned over the data area.
Idle
The drive is spinning., the actuator is parked and powered off,
and all other circuitry is powered on. The drive is capable of
responding to read commands within 40 ms.
Read/Write
Data is being read from or written to the drive.
Spin-up
The drive is spinning up following initial application of power and
has yet not reached full speed. Maximum current draw lasts one
second.
Sleep
This is the lowest power state. The interface becomes inactive. A
software or hardware reset is required to return the drive to
Standby.
Standby
The spin motor is not spinning. The drive will leave this mode
upon receipt of a command that requires disk access.
The time-out value for this mode is programmable. The buffer is
active to accept write data.