8 2 1 6 0 D 2 D I A M O N D M A X MAXTOR
Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders | 4465| |
Capacity form/unform 2160/ MB Heads 2| 15| |
Seek time / track 9.7/ 1.0 ms Sector/track | 63| |
Controller IDE / ATA4 ULTRA Precompensation
Cache/Buffer 256 KB EDO DRAM Landing Zone
Data transfer rate MB/S int Bytes/Sector 512
33.000 MB/S ext UDMA
Recording method operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 55 | -40 71
Power: sleep W Humidity % 5 95 |
standby 0.7 W Altitude km -0.061 3.048| -0.061 12.192
idle 4.0 W Shock g 20 | 150
seek 8.5 W Rotation RPM 5200
read/write 5.0 W Acoustic dBA 37
spin-up 14.0 W ECC Bit SMART
MTBF h
Warranty Month 36
Lift/Lock/Park YES Certificates
MAXTOR 82160D2/83240D3/84320D4/86480D6/88400D8 JUMPER SETTING
Pin 1
J1 IDE Connector | J2 Power
+----------- --------+-++-----------++---------+
| .................... || * * * * || X X X X |
| .......... ......... || * * * * * || X X X X |
+----------------------++-----------++---------+
MAXTOR 82160D2/83240D3/84320D4/86480D6/88400D8 JUMPER SETTING
JUMPER DESIGNATION
|J50|J48|J46|J44|J42|
+-------------------------------------+---+---+---+---+---+
| Master/Slave | | | | | |
| Only Drive in single drive system* | J | | | | |
| Master in a dual drive system* | J | | | | |
| Slave in a dual drive system | O | | | | |
+-------------------------------------+---+---+---+---+---+
| Cable Select | | | | | |
| Disabled* | | O | | | |
| Enabled | | J | | | |
+-------------------------------------+---+---+---+---+---+
| 4092 Cylinder Limitation | | | | | |
| Disabled* | | | O | | |
| Enabled | | | J | | |
+-------------------------------------+---+---+---+---+---+
| Factory Reserved | | | | O | |
+-------------------------------------+---+---+---+---+---+
| Factory Reserved | | | | | O |
+-------------------------------------+---+---+---+---+---+
J=Jumpered O=Open *=Default
Pin 1
J1 IDE Connector | J2 Power
+----------- --------+-++-----------++---------+
| .................... || * : : O || X X X X |
| .......... ......... || * O O O O || X X X X |
+----------------------++-----------++---------+
| | | | | | | | |
| | | | | | | | |
J50 Master/Slave -----+ | | | | | | | + +12V (Yellow)
J48 Cable Select -------+ | | | | | +-- +12V Return (Black)
J46 4092 Cyl Limitation --+ | | | +----- +5V Return (Black)
J44 Factory Reserved -------+ | +------- +5V (Red)
J42 Factory Reserved ---------+
* = Default Jumper Positions
: = "Spare" Jumper Position
O = Default Open Positions