K C 8 0 G A KYOCERA
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/HH Cylinders 787| | |
Capacity form/unform 80/ MB Heads 8| | |
Seek time / track 28.0/10.0 ms Sector/track 26| | |
Controller IDE / AT Precompensation
Cache/Buffer 32 KB Landing Zone
Data transfer rate 1.125 MB/S int Bytes/Sector 512
MB/S ext
Recording method RLL operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C |
Power: sleep W Humidity % |
standby W Altitude km |
idle W Shock g |
seek W Rotation RPM
read/write W Acoustic dBA 40
spin-up W ECC Bit
MTBF h 28000
Warranty Month
Lift/Lock/Park YES Certificates
KYOCERA KC-40GA/80GA PRODUCT DESCRIPTION
+---------------------------------------------------------+ | |XX | +--+J3 |XX I | +-+RESERVED +--+ +-+J1 |XX N | +-+ +-+ |XX T | 1+--+ |XX E | | |J2 |XX R | | | |XX F | +--+ |XX A | |XX C | +-+ External |XX E | | | LED |XX | +-+ |XX | | | |XX Power | |XX +---------------------------------------------------------+
KYOCERA KC-40GA/80GA PRODUCT DESCRIPTION
Jumper setting
--------------
J1 LED
-------
J1 can be shorted on the drive to control a common LED in a two
drive installation. Only the jumper on the drive with the LED should
be CLOSED.
J2 & J3 Drive Select Jumpers ----------------------------- +---------------------------------------+---------------+--------+ |Drive Select | J2/jumper 1 | J3 | +---------------------------------------+---------------+--------+ |Only drive in the system | OPEN | CLOSED| +---------------------------------------+---------------+--------+ |Master drive in two drive system | CLOSED | OPEN | +---------------------------------------+---------------+--------+ |Slave drive in two drive system | OPEN | OPEN | +---------------------------------------+---------------+--------+
J2 User Configurable Jumpers
-------------------------------
+-----------------------------------+--------------+--------+ | Function | Jumper |Position| +-----------------------------------+--------------+--------+ |Auto park enabled | J2/jumper 6 | OPEN | +-----------------------------------+--------------+--------+ |Auto park disabled | J2/jumper 6 | CLOSED | +-----------------------------------+--------------+--------+ |For use with common BIOS | J2/jumper 2 | OPEN | +-----------------------------------+--------------+--------+ |For use with Compaq BIOS | J2/jumper 2 | CLOSED | +-----------------------------------+--------------+--------+
J2/jumper 3-5 are test jumper and should be set "open".