M P C - 3 0 4 3 A T P I C O B I R D FUJITSU
Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 11116| 8940| |
Capacity form/unform 4320/ MB Heads 3| 15| |
Seek time / track 10.5/ 2.0 ms Sector/track | 63| |
Controller ULTRA ATA Precompensation
Cache/Buffer 256 KB Landing Zone
Data transfer rate 14.000 MB/S int Bytes/Sector 512
33.300 MB/S ext UDMA
Recording method EPRML16/17 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 55 | -40 60
Power: sleep W Humidity % 8 80 | 5 85
standby W Altitude km -0.060 3.000| -0.060 12.000
idle 3.8 W Shock g 10 | 75
seek W Rotation RPM 5400
read/write 5.1 W Acoustic dBA
spin-up W ECC Bit SMART
MTBF h 500000
Warranty Month
Lift/Lock/Park YES Certificates
FUJITSU MPC-3032AT/3043/3064/3084/3096AT JUMPER SETTINGS A1CA01675-0
+---------------------------------------------------------+ | |XX | |XXI | |XXN | |XXT | |XXE | |XXR | |XXF | |XXA | |XXC | |XXE | |XX | |+-+Master | || |/Slave | |+-+ | |XX Power | |XX +---------------------------------------------------------+
FUJITSU MPC-3032/3043/3064/3084/3096AT JUMPER SETTING A1CA01675-0030
Jumper Settings
===============
Master Drive ------------ +--2-4-6+ | X * *| | X xxx| +--1-3-5+
Slave Drive ----------- +--2-4-6+ |xxx * *| | * xxx| +--1-3-5+
Cable Select Mode Setting (CSEL)
--------------------------------
Cable select mode gives an alternative method by which the drive may
be set to Master or Slave. A special cable is needed to implement
this features and should only be used if supported by BOTH drives.
+--2-4-6+ | xxx *| | * xxx| +--1-3-5+
********************************************************************
Spare Jumper Settings
---------------------
If the drive cannot be recognized by the system, due to non-
translating BIOS (legacy), which does not allow drives with
capacities greater than 2.1GB, the following jumper setting should be
applied.
Master Drive Setting -------------------- +--2-4-6+ | X * X| | X * X| +--1-3-5+
Slave Drive Setting ------------------- +--2-4-6+ |xxx * X| | * * X| +--1-3-5+
Cable Select Mode Setting (CSEL) -------------------------------- +--2-4-6+ | xxx X| | * * X| +--1-3-5+
FUJITSU MPC AT JUMPER SETTINGS A1CA01675-0030-01
Notes on installation
=====================
Installation direction
----------------------
horizontally vertically
+-----------------+ +--+ +--+
| | | +-----+ +-----+ |
| | | | | | | |
+-+-----------------+-+ | | | | | |
+---------------------+ | | | | | |
| | | | | |
x x | | | | | |
+------x------x-------+ | +-----+ +-----+ |
+-+------x--x-------+-+ +--+ +--+
| xx |
| x x |
+---x--------x----+
x x