M 2 6 8 1 T A M FUJITSU NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 3.5"/SLIMLINE Cylinders 2379| 977| | Capacity form/unform 264/ MB Heads 3| 11| | Seek time / track 14.0/ 4.0 ms Sector/track | 48| | Controller IDE / ATA2 FAST/ENHA Precompensation Cache/Buffer 256 KB Landing Zone Data transfer rate 4.200 MB/S int Bytes/Sector 512 11.100 MB/S ext Recording method RLL 1/7 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 50 | -45 60 Power: sleep W Humidity % 20 80 | 5 95 standby W Altitude km -0.300 3.000| -0.300 12.000 idle W Shock g 5 | 50 seek W Rotation RPM 4500 read/write W Acoustic dBA 43 spin-up W ECC Bit MTBF h 250000 Warranty Month Lift/Lock/Park YES Certificates
FUJITSU M2681T/2682T/2684T JUMPER SETTING C141-E008-IM 1994
+---------------------------------------------------------+ | |XX I | |XX N | |XX T | |XX E | |XX R | |XX F | |XX A | |XX C | |XX E | +-+CN5 |XX | +-+ |XX | |XX | |XX | +-CNH1 |XX | | | | | | | |XX POWER | +-+ |XX +---------------------------------------------------------+
FUJITSU M2681T/2682T/2684T JUMPER SETTING C141-E008-IM 1994
Jumper Setting
==============
x = Factory default
CNH1 1-2 Master/Slave ---------------------- x 1-2 CLOSED Master drive OPEN Slave drive
CNH1 3-4 IORDY I/O Channel Ready signal to interface ----------------------------------------------------- 3-4 CLOSED IORDY connected to Host interface x OPEN IORDY is not connected to Host interface
CNH1 5-6 ACMODE signal to interface ------------------------------------ 5-6 CLOSED ACMODE signal connected to Host interface all power safe commands executed normally x OPEN ACMODE signal is not connected to Host interface all power safe commands are ignored
CNH1 7-8 Automatic idle control -------------------------------- 7-8 CLOSED Automatic idle control is disabled x OPEN Automatic idle control is enabled
CNH1 9-10 Cable Select CSEL mode --------------------------------- x 9-10 OPEN CSEL is not connected to Host interface normal mode CLOSED CSEL is connected to Host interface (Special cable needed)
CNH1 11-12 OPEN
----------------
OPEN DO NOT SHORT
CNH1 13-14 RESERVED
--------------------
CLOSED RESERVED!
FUJITSU => GDT
Tips & Hints about ICP controllers and other peripherals
========================================================
Tagged queues and Fujitsu M 26xx harddisks
------------------------------------------
Fujitsu Harddisks of the M26XX series do not support the SCSI-II
feature tagged queues. You should disable this feature in the
initialize disks menue of the GDTSetup program. An inquiry command
shows, that the harddisk supports tagged queues (this is why you can
enable it in the GDTSetup) but this is not true as stated by Fujitsu
Germany.