lotus

previous page: Hard Drive: FUJITSU: M2652HDB 1860MB 5.25"/FH   SCSI2 D/DU
  
page up: Hard Drive Specs from FUJITSU
  
next page: Hard Drive: FUJITSU: M2652S 1529MB 5.25"/FH   SCSI2 SE

Hard Drive: FUJITSU: M2652P MB 5.25"/FH IPI-2




M 2 6 5 2 P    FUJITSU
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 5.25"/FH              Cylinders    1893|     |     |
Capacity form/unform      / 2001 MB        Heads          20|     |     |
Seek time   / track  11.0/ 2.0 ms          Sector/track     |     |     |
Controller           IPI-2                 Precompensation
Cache/Buffer               KB              Landing Zone
Data transfer rate          MB/S int       Bytes/Sector      512
                      4.760 MB/S ext
Recording method     NRZ 2-OCTE                     operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C        10 45    |    -40 60
Power: sleep              W     Humidity     %        20 80    |      5 95
       standby       45.0 W     Altitude    km            3.000|        12.000
       idle               W     Shock        g         2       |     20
       seek               W     Rotation   RPM      5400
       read/write         W     Acoustic   dBA
       spin-up            W     ECC        Bit
                                MTBF         h     200000
                                Warranty Month
Lift/Lock/Park     YES          Certificates                                  

Layout

FUJITSU M2652P JUMPER SETTING

      +----------------------------------------------------------+
      | +--------------+CN6  1++++ 1++++++++ON  PCA 2            |
      | +--------------+     +++++ +++++++++                     |
      |                       SW1     SW2                        |
    +-+-+              +----------------------------------------+|
    |   +--------------+          +------------------------1    ||
    |       +-------+             +------------------------+CN1 ||
    |       +-------CN3           +------------------------1    ||
    |          ON+++++            +------------------------+CN2 ||
    |            1+++SW1             +-----++-----++-----+      ||
    |                                1-----+1-----+1-----+PORT A||
    |                                +-----++-----++-----+      ||
    |                                1-----+1-----+1-----+PORT B||
    |                                   Resistor Modules        ||
    |                                                   +-------+|
    |   PCA 1                                           |+-------+
    ++--------------------------------------------------+|XXXXXXX
     +---------------------------------------------------+Power

Jumpers

FUJITSU M2652P JUMPER SETTING

Jumper Setting
==============

SW1 PCA-2
=========

 Setting the drive logical address
 ---------------------------------
   +----------+-----------------------+
   | SCSI ID  |        Jumpers        |
   |          |   3   |   2   |   1   |
   +----------+-------+-------+-------+
   |    0     | OPEN  | OPEN  | OPEN  |
   +----------+-------+-------+-------+
   |    1     | OPEN  | OPEN  | CLOSED|
   +----------+-------+-------+-------+
   |    2     | OPEN  | CLOSED| OPEN  |
   +----------+-------+-------+-------+
   |    3     | OPEN  | CLOSED| CLOSED|
   +----------+-------+-------+-------+
   |    4     | CLOSED| OPEN  | OPEN  |
   +----------+-------+-------+-------+
   |    5     | CLOSED| OPEN  | CLOSED|
   +----------+-------+-------+-------+
   |    6     | CLOSED| CLOSED| OPEN  |
   +----------+-------+-------+-------+
   |    7     | CLOSED| CLOSED| CLOSED|
   +----------+-------+-------+-------+
   CLOSED = ON
   OPEN   = OFF

 Write protection
 ----------------
        4       OFF     Write enable
                ON      Write protect

 PCA-2 DIP SW2
 ==============
 Port A/B enable
 ---------------
        1       OFF     Port A enable
                ON      Port A disable

        2       OFF     Port B enable
                ON      Port B disable

 Local spin-up
 -------------
        3       OFF     Spin-up control from controller
                ON      Spin-up on power up

 Spindle sync mode setting
 -------------------------
        4       OFF     Spindle sync disable
                ON      Spindle sync enable

        5       6
        OFF     OFF     Local Slave
        OFF     ON      Local Master
        ON      n/a     Spindle Sync command mode
                        These settings are only valid if Key 4 is ON

 Short RPS enable
 ----------------
        7       OFF     Disable
                ON      Enable
                        The short RPS function enables the drive to generate an
                        interrupt to the master during the time that the heads are
                        over any port of the RPS pulse.

 RPS option parameter
 --------------------
        8       OFF     Enable
                ON      Disable
                        As the Extension, RPS pulse width and skew are not
                        transferred, only a short RPS function is available. This
                        switch must be turned on before power is administered,
                        otherwise the Selective Reset with Reset Drive must be
                        issued.

PCA-1 DIP SW1
==============
Spindle sync termination and line bias

   | 1 | 2 | 3 | 4 |
  -+---+---+---+---+------------------------------
   |OFF|OFF|OFF|OFF|non-bias and non termination
  -+---+---+---+---+------------------------------
   |OFF|ON |ON |OFF|on-bias (termination)
  -+---+---+---+---+------------------------------
   |ON |ON |ON |ON |bias

Install

FUJITSU M2652P INSTALLATION NOTES

Notes on installation
=====================

Drive mounting
--------------

     horizontally             vertically
   +-----------------+   +--+             +--+ +------------------+
   |                 |   |  +-----+ +-----+  | |                  | x
   |                 |   |  |     | |     |  | x+----------------+x
 +-+-----------------+-+ |  |     | |     |  | ||x              x||
 +---------------------+ |  |     | |     |  | ||  x          x  ||
                         |  |     | |     |  | ||    x      x    ||
      x           x      |  |     | |     |  | ||      x  x      ||
 +------x------x-------+ |  +-----+ +-----+  | ||       xx       ||
 +-+------x--x-------+-+ +--+             +--+ ||     x    x     ||
   |       xx        |                         ||   x        x   ||
   |     x    x      |                         || x            x ||
   +---x--------x----+                         |x                x|
     x            x                           x++----------------++x
      UNACCEPTABLE!                                UNACCEPTABLE!

Power Requirements
==================

 Power connector pin assignment:                4  3  2  1
 (As viewed from cable side of connector)
                                        1 + 12 V
                                        2 + 12 V RTN
                                        3 +  5 V RTN
                                        4 +  5 V

Notes on Installation
=====================

 Installation direction: The drive may be installed either PCA down
                         or on edge. Inclination from vertical
                         should be less than 5*.

 Mounting screws:        Either side or underside mounting may be
                         used. Standard drive use M3 screws but some
                         special models and US versions use 6/32 UNC.
                         Screws should not protrude from the drive
                         frame by more than 3mm or damage may occur.

 Frame clearance:        There should be a gap of at least 2.5mm
                         between the drive and the system mounting
                         frame on all sides to provide adequate sway
                         space for shock protection.

 Grounding:              It is strongly recommended that the Disk
                         Enclosure is connected to the system frame
                         ground via the 'faston' connector on the back
                         of the drive.

 Cooling:                Cooling should be provided to keep the DE
                         surface temperature (measured at the centre
                         of the top of the drive) below 55*C.

Features

FUJITSU M2652P NOTES ON INSTALLATION

Media Defects
============
Media Defect List:
Before the unit leaves the factory, media defects are listed
on the MEDIA DEFECT LIST. This list is attached to the Disk
Enclosure and is also written on the media in a reserved
area of the disk.

NOTE 1:
It is recommended that the media defect list be used when formatting
the drive before use. Any media defects that occur once the drive
is installed may be mapped out by the operating system. See system
documentation for details of the defect management schemes available.

Note 1 : Max. media defects at time of shipment:

                                                M2652P, 600 or less

Note 2 : No track has more than 4 defects.

 Note 3 : Cylinder 0 heads 0 - 2 and cylinder 1892 head 19 are defect
          free areas.

General

FUJITSU => GDT

Tips & Hints about ICP controllers and other peripherals
========================================================

Tagged queues and Fujitsu M 26xx harddisks
------------------------------------------
Fujitsu Harddisks of the M26XX series do not support the SCSI-II
feature tagged queues. You should disable this feature in the
initialize disks menue of the GDTSetup program. An inquiry command
shows, that the harddisk supports tagged queues (this is why you can
enable it in the GDTSetup) but this is not true as stated by Fujitsu
Germany.













TOP
previous page: Hard Drive: FUJITSU: M2652HDB 1860MB 5.25"/FH   SCSI2 D/DU
  
page up: Hard Drive Specs from FUJITSU
  
next page: Hard Drive: FUJITSU: M2652S 1529MB 5.25"/FH   SCSI2 SE