lotus

previous page: Hard Drive: FUJITSU: M2614T 180MB 3.5"/HH    IDE / AT
  
page up: Hard Drive Specs from FUJITSU
  
next page: Hard Drive: FUJITSU: M2615ESA 52MB 3.5"/SL    SCSI1 SE

Hard Drive: FUJITSU: M2615ES 52MB 3.5"/SL SCSI1 SE




M 2 6 1 5 E S    FUJITSU
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 3.5"/SLIMLINE         Cylinders    1542|     |     |
Capacity form/unform    52/      MB        Heads           2|     |     |
Seek time   / track  20.0/ 8.0 ms          Sector/track   68|     |     |
Controller           SCSI1 SINGLE-ENDED    Precompensation
Cache/Buffer            24 KB RING BUFFER  Landing Zone
Data transfer rate          MB/S int       Bytes/Sector      256
                      2.500 MB/S ext SYNC
Recording method     RLL 1/7                        operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C         5 45    |    -40 60
Power: sleep              W     Humidity     %        20 80    |      5 95
       standby        9.2 W     Altitude    km    -0.060  3.000|        12.000
       idle               W     Shock        g         5       |     50
       seek               W     Rotation   RPM      3490
       read/write         W     Acoustic   dBA        43
       spin-up            W     ECC        Bit   56
                                MTBF         h      50000
                                Warranty Month
Lift/Lock/Park     YES          Certificates                                  

Layout

FUJITSU M2615/M2616-ES/ESA/ESB OEM MANUAL 41FH5062E-02

  +---------------------------------------------------------+
  |                                                 +---+   |XX 50
  |     +------+                  +--------+        |   |   |XX
  |     |      |   +----------+   |        |  Terminator|   |XX
  |     |      |   |          |   |        |        |   |   |XX
  |     +------+   |          |   |        |        +-x-+   |XX
  |                +----------+   +--------+         +--+11 |XX
  |                                                  |  |   |XX SCSI
  | +--+                     +--+              CNH-1 |  |   |XX
  | +--+                     |x |1                   |  |   |XX
  | CN6/LED              OFF | x| ON                 |  |   |XX
  |                          |x |                    +--+ 1 |XX
  |                          |x |4                   +--+ 9 |XX
  |                          +--+                    |  |   |XX 1
  |                       DIP switch           CNH-2 |  |   |
  |                                                  |  |   |
  |                                                  |  |   |XX Power
  |                                                  +--+ 1 |XX
  +---------------------------------------------------------+

Jumpers

FUJITSU M2615/M2616-ES/ESA/ESB OEM MANUAL 41FH5062E-02

Jumper Settings
===============
x = Jumpers are set from factory

 CNH1  SCSI bus parity option
 ----------------------------
 x      1-2 CLOSE   SCSI bus parity is enabled
        2-3 CLOSE   SCSI bus parity is disabled

 CNH1  Synchronous transfer mode
 -------------------------------
 x      4-5 CLOSE   Synchronous transfer is enabled
        5-6 CLOSE   Synchronous transfer is disabled

 CNH1  SCSI terminator power
 ---------------------------
 x      7- 8 CLOSE   Power source for IDD terminator
 x     10-11 CLOSE   -------------------------------
                     o    SCSI bus terminator power source is used
                     #    IDD terminator power source is used
                     Others
                     ------
                     #    IDD supplies bus terminator power source

        8- 9 CLOSE   Power source for IDD terminator
       10-11 CLOSE   -------------------------------
                     x    SCSI bus terminator power source is used
                     *    IDD terminator power source is used
                     Others
                     ------
                     x    IDD supplies bus terminator power source

        7- 8 CLOSE   Power source for IDD terminator
        9-10 CLOSE   -------------------------------
                     *    SCSI bus terminator power source is used
                     x    IDD terminator power source is used
                     Others
                     ------
                     x    IDD supplies bus terminator power source

       o  =  Bus terminator power voltage > IDD terminator power volt.
       #  =  Bus terminator power voltage < IDD terminator power volt.
       *  =  any condition

       Power sypply for terminator (+5VDC)
       +-----------------------------------------------------+
       |                     +----- CNH-1 -----+   -+- +5V DC|
      +++                    | 7  8  9  10  11 |    |        |
        | TERMPER +------+   +-+--+--+--+----+-+    + Diode  |
      S *---------+ FUSE +-----+  |  |  |    +------+        |
      C |         +------+        +--+--+----+               |
      S |                             +------+-----+         |
      I *-----------------------------+ Terminator |         |
        | SIGNAL                      | Circuit    |         |
      +++                             +------+-----+         |
       |                                     + GND           |
       +-----------------------------------------------------+

 CNH2  SCSI ID
 -------------
                     | SCSI ID
       --------------+--------
       2-3  5-6  8-9 |    0
       1-2  5-6  8-9 |    1
       2-3  4-5  8-9 |    2
       1-2  4-5  8-9 |    3
       2-3  5-6  7-8 |    4
       1-2  5-6  7-8 |    5
       2-3  4-5  7-8 |    6
       1-2  4-5  7-8 |    7

 DIP   Write protect
 -------------------
        1   ON       Write Protect
 x      1   OFF      Non Write Protect

 DIP   Motor control
 -------------------
 x      2   ON       Self starting
        2   OFF      Waiting MOTOR START Command

 DIP   Self Diagnostic Switch
 ----------------------------
        3   ON       Normal mode
 x      3   OFF      Test mode

 DIP   Not used
 --------------
        4   ON
 x      4   OFF      MUST BE OFF!

Install

FUJITSU M2615/M2616-ES/ESA/ESB OEM MANUAL 41FH5062E-02

Notes on installation
=====================

Installation direction
----------------------

     horizontally                           vertically
   +-----------------+           +--+                      +--+
   |                 |           |  +-----+          +-----+  |
   |                 |           |  |     |          |     |  |
 +-+-----------------+-+         |  |     |          |     |  |
 +---------------------+         |  |     |          |     |  |
                                 |  |     |          |     |  |
      x           x              |  |     |          |     |  |
 +------x------x-------+         |  +-----+          +-----+  |
 +-+------x--x-------+-+         +--+                      +--+
   |       xx        |
   |     x    x      |
   +---x--------x----+
     x              x

There are three possible installation directions, and the mounting
angle must be true within 5* from the horizontal.

Ambient temperature
-------------------
The operating temperature range of the drive is specified at a dis-
tance of 3 cm from the drive.

Make shure to maintain the base temperature range of DE from 5*C to
58*C.

Cable requirements
------------------
A characteristic impedance of 100 10% is recommended for the un-
shielded twisted-pair ribbon cable. Characteristic impedance greater
than 90 is preferred for the shielded cable. A minimum conductor
size of 28 AWG shall be employed. It is recommended that the shielded
cable be uses for connection outside the system cabinet.

To minimize discontinuities and signal refelections, cables of dif-
ferent impedance should not be used on the same bus. The maximum
cable length is 6m. A cable length of 1m or more is recommended be-
tween SCSI devices.

Multi-drive connections
-----------------------
Host systems, IDDs, and other SCSI controllers can be connected
(daisy-chained) to SCSI provided that the total number of SCSI
devices connected does not exeed eigth.

 Terminator
 ----------
 Terminator is already installed in IDD at shipment. Remove the ter-
 minator if the IDD is not installed at beginning or ending position
 of SCSI cable.
                       +5V DC
            ----------+----------
                     +++
                     | | 220   2%
            - Signal +++
            ----------+
                     +++
                     | | 330   2%
            GND      +++
            ----------+
                      |
                     -+-

External LED Connector
-----------------------
The user can connect the external LED to the drive if necessary. The
external LED is connected to CN6 on the PCA.

AC line noise
-------------
To eliminate AC line noise, a noise filter should be incorporated in
the AC input terminal of the drvie power supply.
Attenuation characteristics: 40dB or greater at 10MHz
Circuit configuration: T type

Features

FUJITSU M2615/M2616-ES/ESA/ESB OEM MANUAL 41FH5062E-02

24KB data buffer
-----------------
To improve system throughput, the IDD contains a 24KB ring buffer.

SCSI bus configuration
----------------------
Up to eight SCSI devices can be connected to the SCSI bus, with any
combination of the SCSI devices that operate as initiator and that
operate as target.

Each SCSI device on the bus has its own unique address (SCSI-ID: #n).
For input/output operation, a peripheral device attached to the SCSI
bus that operates as target is addressed in unit called as logical
unit. A unique address (LUN: logical unit number) is assigned for
each logical unit.

   +-------------+  +-------------+  SCSI bus +----------+LUN=0
   | Host system +--+Host Adapter +-------+---+ IDD      |(fixed)
   |             |  |  ID #7      |       |   |   ID #0  |
   +-------------+  +-------------+       |   +----------+
                                          |   +----------+LUN=0
                                          +---+ IDD      |(fixed)
                                          |   |   ID #1  |
                                          |   +----------+
                                          |   +------------+
                                          +---+ Controller +--+----+--
                                          |   |   ID #2    | LUN0 LUN1
                                          |   +------------+

Mean Time Between Failures (MTBF)
---------------------------------
The estimated MTBF of the IDD during its life time is 50.000 hours.

Failure of the equipment means failure that requires repairs, adjust-
ments or replacements. Mishandling by the operator, failures due to
bad environmental conditions, power trouble, controller trouble,
cable failures or other failures not caused by the equipment are not
included.

Mean Time To Repair (MTTR)
--------------------------
MTTR is the average time taken ba a well-trined service mechanic to
diagnose and repair a drive malfunction. The drive is designed for a
MTTR of 30 minutes or less.

Service life
------------
Overhaul of the drive is not required for the first five years or the
first 20.000 hours.

Data security at power failure
------------------------------
Integrity of the data on the disk is guaranteed against all forms of
DC power failure except a power failure during a write operation.

General

FUJITSU => GDT

Tips & Hints about ICP controllers and other peripherals
========================================================

Tagged queues and Fujitsu M 26xx harddisks
------------------------------------------
Fujitsu Harddisks of the M26XX series do not support the SCSI-II
feature tagged queues. You should disable this feature in the
initialize disks menue of the GDTSetup program. An inquiry command
shows, that the harddisk supports tagged queues (this is why you can
enable it in the GDTSetup) but this is not true as stated by Fujitsu
Germany.













TOP
previous page: Hard Drive: FUJITSU: M2614T 180MB 3.5"/HH    IDE / AT
  
page up: Hard Drive Specs from FUJITSU
  
next page: Hard Drive: FUJITSU: M2615ESA 52MB 3.5"/SL    SCSI1 SE