M 2 6 1 2 E S A FUJITSU
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/HH Cylinders 1334| | |
Capacity form/unform 90/ MB Heads 4| | |
Seek time / track 20.0/ 8.0 ms Sector/track 34| | |
Controller SCSI1 SINGLE-ENDED Precompensation
Cache/Buffer 24 KB RING BUFFER Landing Zone
Data transfer rate MB/S int Bytes/Sector 512
2.500 MB/S ext SYNC
Recording method RLL 1/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 45 | -40 60
Power: sleep W Humidity % 20 80 | 5 95
standby W Altitude km -0.060 3.000| 12.000
idle W Shock g 5 | 50
seek 10.4 W Rotation RPM 3490
read/write W Acoustic dBA 43
spin-up W ECC Bit -
MTBF h 50000
Warranty Month
Lift/Lock/Park YES Certificates
FUJITSU M2612/M2613/M2614-ES/ESA/ESB OEM MANUAL 41FH5058E-03
+---------------------------------------------------------+ | +---+ |XX | +------+ +--------+ | | |XX | | | +----------+ | | Terminator| |XX | | | | | | | | | |XX | +------+ | | | | +-x-+ |XX | +----------+ +--------+ +--+11 |XX | | | |XX | +--+ +--+ CNH-1 | | |XX | +--+ |x |1 | | |XX | CN6/LED OFF | x| ON | | |XX | |x | +--+ 1 |XX | |x |4 +--+ 9 |XX | +--+ | | |XX | DIP switch CNH-2 | | | | | | | | | | |XX Power | +--+ 1 |XX +---------------------------------------------------------+
FUJITSU M2612/M2613/M2614-ES/ESA/ESB OEM MANUAL 41FH5058E-03
Jumper Settings
===============
x = Jumpers are set from factory
CNH1 SCSI bus parity option
----------------------------
x 1- 2 CLOSE SCSI bus parity is enabled
2- 3 CLOSE SCSI bus parity is disabled
CNH1 Synchronous transfer mode
-------------------------------
x 4- 5 CLOSE Synchronous
5- 6 CLOSE Asynchronous
CNH1 SCSI terminator power
---------------------------
x 7- 8 CLOSE Power source for IDD terminator
x 10-11 CLOSE -------------------------------
o SCSI bus terminator power source is used
# IDD terminator power source is used
Others
------
# IDD supplies bus terminator power source
8- 9 CLOSE Power source for IDD terminator
10-11 CLOSE -------------------------------
x SCSI bus terminator power source is used
* IDD terminator power source is used
Others
------
x IDD supplies bus terminator power source
7- 8 CLOSE Power source for IDD terminator
9-10 CLOSE -------------------------------
* SCSI bus terminator power source is used
x IDD terminator power source is used
Others
------
x IDD supplies bus terminator power source
o = Bus terminator power voltage > IDD terminator power volt.
# = Bus terminator power voltage < IDD terminator power volt.
* = any condition
Power sypply for terminator (+5VDC)
+-----------------------------------------------------+
| +----- CNH-1 -----+ -+- +5V DC|
+++ | 7 8 9 10 11 | | |
| TERMPER +------+ +-+--+--+--+----+-+ + Diode |
S *---------+ FUSE +-----+ | | | +------+ |
C | +------+ +--+--+----+ |
S | +------+-----+ |
I *-----------------------------+ Terminator | |
| SIGNAL | Circuit | |
+++ +------+-----+ |
| + GND |
+-----------------------------------------------------+
CNH2 SCSI ID / Drive select
----------------------------
1- 2 CLOSE Bit 0 ON
x 2- 3 CLOSE OFF
4- 5 CLOSE Bit 1 ON
x 5- 6 CLOSE OFF
7- 8 CLOSE Bit 2 ON
x 8- 9 CLOSE OFF
DIP Write protect
-------------------
1 ON Write Protect
x 1 OFF No Write Protect
DIP Motor control
-------------------
x 2 ON Self starting mode
2 OFF Wait for Motor Start/Stop Command
The starting method of the disk drive spindle motor may be
adjusted by by the setting switch on the IDD. If this switch
is set to inhibit motor start control, the spindle motor starts
immediately after the IDD is turned on. If the setting switch
is set to enable motor start control, the motor does not start
if the IDD is turned on. In this case, a command is used to
start the spindle motor.
DIP Self Diagnostic Switch
----------------------------
3 ON Normal mode
x 3 OFF Self-diagnostic mode
DIP Not used
--------------
4 ON
x 4 OFF MUST BE OFF!
FUJITSU M2612/M2613/M2614-ES/ESA/ESB OEM MANUAL 41FH5058E-03
Notes on installation
=====================
Installation direction
----------------------
horizontally vertically
+-----------------+ +--+ +--+
| | | +-----+ +-----+ |
| | | | | | | |
+-+-----------------+-+ | | | | | |
+---------------------+ | | | | | |
| | | | | |
x x | | | | | |
+------x------x-------+ | +-----+ +-----+ |
+-+------x--x-------+-+ +--+ +--+
| xx |
| x x |
+---x--------x----+
x x
There are three possible installation directions, and the mounting
angle must be 5* from the horizontal.
Dont install the PCA on the top!
Ambient temperature
-------------------
The operating temperature range of the drive is specified at a dis-
tance of 3 cm from the drive. Note, temperature specifications are
for the outside air surrounding the drive.
Make shure to maintain the base temperature range of DE from 5*C to
58*C.
Multi-drive connection
----------------------
Host systems, IDDs, and other SCSI controllers can be connected
(daisy-chained) to SCSI provided that the total number of SCSI de-
vices connected does not exceed eight.
Cable requirements
------------------
A characteristic impedance of 100 10% is recommended for the un-
shielded twisted-pair ribbon cable. Characteristic impedance greater
than 90 is preferred for the shielded cable. A minimum conductor
size of 28 AWG shall be employed. It is recommended that the shielded
cable be uses for connection outside the system cabinet.
To minimize discontinuities and signal refelections, cables of dif-
ferent impedance should not be used on the same bus. The maximum
cable length is 7m. A cable length of 1m or more is recommended be-
tween SCSI devices.
Terminator
----------
Terminator is already installed in IDD at shipment. Remove the ter-
minator if the IDD is not installed at beginning or ending position
of SCSI cable. The terminator is only installed on the controller
PCA when the IDD is connected to the beginning or ending position
of SCSI cable.
External LED Connection
-----------------------
The user can connect the external LED to the drive if necessary. The
external LED is connected to CN6 on the PCA.
FUJITSU => GDT
Tips & Hints about ICP controllers and other peripherals
========================================================
Tagged queues and Fujitsu M 26xx harddisks
------------------------------------------
Fujitsu Harddisks of the M26XX series do not support the SCSI-II
feature tagged queues. You should disable this feature in the
initialize disks menue of the GDTSetup program. An inquiry command
shows, that the harddisk supports tagged queues (this is why you can
enable it in the GDTSetup) but this is not true as stated by Fujitsu
Germany.