lotus

previous page: Hard Drive: CONNER: CFP-4207WD    CAYMAN 4295MB 3.5"/HH    SCSI3 D/WI
  
page up: Hard Drive Specs from CONNER
  
next page: Hard Drive: CONNER: CFS-1060A       CABO 1065MB 3.5"/SL    ATA2 FAST

Hard Drive: CONNER: CFP-4207WV CAYMAN AV 4294MB 3.5"/SL SCSI2 WIDE




C F P - 4 2 0 7 W V   C A Y M A N   A V    CONNER
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 3.5"/SLIMLINE         Cylinders    4016|     |     |
Capacity form/unform  4294/      MB        Heads          20|     |     |
Seek time   / track   8.5/ 2.0 ms          Sector/track     |     |     |
Controller           SCSI2 SI/WI/FAS/AV    Precompensation
Cache/Buffer           512 KB              Landing Zone
Data transfer rate    6.700 MB/S int       Bytes/Sector      512
                     20.000 MB/S ext
Recording method                                    operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C         5 55    |    -40 60
Power: sleep              W     Humidity     %         5 95    |      5 95
       standby            W     Altitude    km    -0.061  3.048|        12.192
       idle          12.8 W     Shock        g         5       |     50
       seek          14.3 W     Rotation   RPM      7200
       read/write    13.2 W     Acoustic   dBA
       spin-up            W     ECC        Bit
                                MTBF         h    1000000
                                Warranty Month
Lift/Lock/Park     YES          Certificates                                  

Layout

CONNER CFP-4207W QUICK REFERENCE GUIDE 12/94 REV. C

  +---------------------------------------------------------++---+
  |      +-J1                                          ++++ ||XX J2
  |      | |                                           |||| ||XX |68
  |      | |                                           |||| ||XX |Pin
  |      | |                                           |||| ||XX |
  |      +-+                                           |||| ||XX |
  |                                                    *+*+ ||XX |
  |                                                    E8++ ||XX |
  |                                                      ++ ||XX |
  |                                              (Fuse)F1xx ||XX1|
  |  J3                                                  ++ ||+-+|
  | +-+ SS                         ++++++++              || ||| |J5
  | | | LED                        ++++++++              || ||| ||
  | | |                          E1 ****** E7            || ||| ||
  | +-+                                                  || ||+-1|
  |                                                      *+ ||xx |
 ++                                                         ||XX J4
 ++LED                                                      ||XX Power
  +---------------------------------------------------------++--1+

Jumpers

CONNER CFP-4207W QUICK REFERENCE 12/1994, REV. C

Jumper Setting
==============

Setting the SCSI Bus Address
----------------------------
There are four jumpers available for configuration of the SCSI ID:
E1, E2, E3 and E4.

 Setting the SCSI ID
 -------------------
  +-------+----------+----------+----------+----------+
  |SCSI ID|    E1    |    E2    |   E3     |   E4     |
  +-------+----------+----------+----------+----------+
  |  0    |OUT/OPEN  |OUT/OPEN  |OUT/OPEN  |OUT/OPEN  |
  +-------+----------+----------+----------+----------+
  |  1    |IN /GROUND|OUT/OPEN  |OUT/OPEN  |OUT/OPEN  |
  +-------+----------+----------+----------+----------+
  |  2    |OUT/OPEN  |IN /GROUND|OUT/OPEN  |OUT/OPEN  |
  +-------+----------+----------+----------+----------+
  |  3    |IN /GROUND|IN /GROUND|OUT/OPEN  |OUT/OPEN  |
  +-------+----------+----------+----------+----------+
  |  4    |OUT/OPEN  |OUT/OPEN  |IN /GROUND|OUT/OPEN  |
  +-------+----------+----------+----------+----------+
  |  5    |IN /GROUND|OUT/OPEN  |IN /GROUND|OUT/OPEN  |
  +-------+----------+----------+----------+----------+
  |  6    |OUT/OPEN  |IN /GROUND|IN /GROUND|OUT/OPEN  |
  +-------+----------+----------+----------+----------+
  |  7    |IN /GROUND|IN /GROUND|IN /GROUND|OUT/OPEN  |
  +-------+----------+----------+----------+----------+
  |  8    |OUT/OPEN  |OUT/OPEN  |OUT/OPEN  |IN /GROUND|
  +-------+----------+----------+----------+----------+
  |  9    |IN /GROUND|OUT/OPEN  |OUT/OPEN  |IN /GROUND|
  +-------+----------+----------+----------+----------+
  | 10    |OUT/OPEN  |IN /GROUND|OUT/OPEN  |IN /GROUND|
  +-------+----------+----------+----------+----------+
  | 11    |IN /GROUND|IN /GROUND|OUT/OPEN  |IN /GROUND|
  +-------+----------+----------+----------+----------+
  | 12    |OUT/OPEN  |OUT/OPEN  |IN /GROUND|IN /GROUND|
  +-------+----------+----------+----------+----------+
  | 13    |IN /GROUND|OUT/OPEN  |IN /GROUND|IN /GROUND|
  +-------+----------+----------+----------+----------+
  | 14    |OUT/OPEN  |IN /GROUND|IN /GROUND|IN /GROUND|
  +-------+----------+----------+----------+----------+
  | 15    |IN /GROUND|IN /GROUND|IN /GROUND|IN /GROUND|
  +-------+----------+----------+----------+----------+
   Open means open circuit or high impedance. Ground means
   TTL logic low or logic ground.

 Disabling Spin-Up at Power On
 -----------------------------
 A jumper in the E5 location, disables spin up after power-on for
 applications where spin up sequencing is necessary. Disabling spin up
 on application of power can also be enabled by setting the DSPN bit
 in MODE SELECT page 00H (Operating Parameters). The Host must issue a
 Start UNIT command to cause the drive to spin up.
   +---------+------+---------------------+
   |   E5    | DSPN | Result              |
   +---------+------+---------------------+
   |   IN    |  0   | Spin Disabled       |
   +---------+------+---------------------+
   |   IN    |  1   | Spin Disabled       |
   +---------+------+---------------------+
   |   OUT   |  0   | Spin up on Power On |
   +---------+------+---------------------+
   |   OUT   |  1   | Spin Disabled       |
   +---------+------+---------------------+

Delaying Spin Up at Power On
----------------------------
A jumper in the E6 location, delays spin up on power-up by the value
of the drive's SCSI ID multiplied by 4 seconds (i.e. SCSI ID 4 will
delay 16 seconds). Delaying spin up on application of power can also
be enabled by setting the SDLY bit in MODE SELECT page 00H (Operating
Parameters.)

   +---------+------+---------------------+
   |   E6    | SDLY | Result              |
   +---------+------+---------------------+
   |   IN    |  0   | Spin Delayed        |
   +---------+------+---------------------+
   |   IN    |  1   | Spin Delayed        |
   +---------+------+---------------------+
   |   OUT   |  0   | Spin up on Power On |
   +---------+------+---------------------+
   |   OUT   |  1   | Spin Delayed        |
   +---------+------+---------------------+

Disabling the SCSI Bus Parity
-----------------------------
SCSI parity is always enabled in both directions, unless the E7
Parity disable jumper is installed. Installing the jumper will cause
the drive to ignore SCSI bus Parity In but it will continue to
generate SCSI bus parity out.

Disabling SCSI Bus Terminator Power (TERMPWR)
---------------------------------------------
Power to the on-board terminators is provided by the higher of the
voltage supplied at Pin #17, 18, 51 & 52, J2 or the voltage level at
the 5 Volt power input to the drive minus one diode drop. Termination
Power to external terminators can be supplied by the drive through
Pin #17, 18, 51 & 52, J2. The TERMPWR line can be disconnected from
the drive by removing Jumper E8.

 Jumper E8 | Result
 ----------+----------------------------------------------------
   IN      | TERMPWR (J2, Pin #17, 18, 51 & 52) connected to the
           | drive's internal termination power.
 ----------+----------------------------------------------------
   OUT     | TERMPWR (J2, Pin #17, 18, 51 & 52) open circuit.

Setting the Bus Termination
---------------------------
Remove the SCSI Terminators in all but the last drive in the chain.













TOP
previous page: Hard Drive: CONNER: CFP-4207WD    CAYMAN 4295MB 3.5"/HH    SCSI3 D/WI
  
page up: Hard Drive Specs from CONNER
  
next page: Hard Drive: CONNER: CFS-1060A       CABO 1065MB 3.5"/SL    ATA2 FAST