ZOBEX
ZOBEX 4HDC-62W
Data Bus | 8-bit ISA |
Card Size | Three-quarter length, full-height card |
Hard Drives supported | Four ST-506/412(MFM) drives |
Floppy drives supported | None |
CONNECTIONS | |||
Function | Location | Function | Location |
34-pin control cable connector | J1 | 20-pin data cable connector | J4 |
20-pin data cable connector - drive 0 | J2 | 20-pin data cable connector | J5 |
20-pin data cable connector - drive 1 | J3 |
USER CONFIGURABLE SETTINGS | |||
Function | Label | Position | |
» | IRQ 5 enable | JP4/1 | Closed |
IRQ 5 disable | JP4/1 | Open | |
» | Factory configured - do not alter | P2 | Open |
» | Write Protect drive 0 disabled | P3/pins 1 & 2 | Open |
Write Protect drive 0 enabled | P3/pins 1 & 2 | Closed | |
» | Write Protect drive 1 disabled | P3/pins 3 & 4 | Open |
Write Protect drive 1 enabled | P3/pins 3 & 4 | Closed | |
» | Write Protect drive 2 disabled | P3/pins 5 & 6 | Open |
Write Protect drive 2 enabled | P3/pins 5 & 6 | Closed | |
» | Write Protect drive 3 disabled | P3/pins 7 & 8 | Open |
Write Protect drive 3 enabled | P3/pins 7 & 8 | Closed | |
» | Factory configured - do not alter (Ext. Stat. Reg. Bit 4) | SW1/1 | Off |
» | Factory configured - do not alter (Ext. Stat. Reg. Bit 5) | SW1/2 | Off |
» | Factory configured - do not alter (Ext. Stat. Reg. Bit 6) | SW1/3 | Off |
» | Factory configured - do not alter (Ext. Stat. Reg. Bit 7) | SW1/4 | Off |
» | Factory configured - do not alter | SW2/7 | Unidentified |
» | Factory configured - do not alter | SW2/8 | Unidentified |
PIN 2 CABLE SELECTION FOR CABLE J1 | |||||
Setting | P1/1 | P1/2 | P1/3 | P1/4 | |
Change Cartridge Signal | Open | Open | Open | Closed | |
Head Select | Open | Open | Closed | Open | |
» | Reduced Write Current | Open | Closed | Open | Open |
Disable pin 2 3 | Closed | Open | Open | Open | |
Note: Select the ‘Head Select’ setting if the attached drive is large capacity with more than 8 heads. |
DMA CHANNEL SELECTION | |||
Channel | JP4/1 | JP4/2 | |
» | DMA 3 disabled | Open | Open |
DMA 3 enabled | Closed | Closed |
BASE ADDRESS SELECTION | |||||||
Setting | SW2/1 | SW2/2 | SW2/3 | SW2/4 | SW2/5 | SW2/6 | |
» | 300h | On | On | On | Off | Off | On |