ULTRASTOR CORPORATION
ULTRA 14FB
Data bus: | 16-bit, ISA |
Size: | Three/quarter-length, full-height card |
Hard drive supported: | Up to seven SCSI drives |
Floppy drives supported: | Two 360KB, 720KB, 1.2MB, or 1.44MB drives |
CONNECTIONS | |
Function | Location |
50-pin SCSI connector - internal | J1 |
50-pin SCSI connector - external | J2 |
34-pin control cable connector - floppy drive | J3 |
4-pin connector - Drive active LED | JP3 |
BIOS ADDRESS* | ||||
Address | JP11/jumper 1 | JP11/jumper 2 | JP11/jumper 3 | |
» | Disabled | open | open | open |
C400h | open | open | closed | |
C800h | open | closed | open | |
CC00h | open | closed | closed | |
D000h | closed | open | open | |
D400h | closed | open | closed | |
D800h | closed | closed | open | |
DC00h | closed | closed | closed |
I/O PORT ADDRESS* | |||
Address | JP12/jumper 1 | JP12/jumper 2 | JP12/jumper 3 |
330h | open | open | open |
340h | open | open | closed |
310h | open | closed | open |
230h | open | closed | closed |
240h | closed | open | open |
210h | closed | open | closed |
130h | closed | closed | open |
140h | closed | closed | closed |
USER CONFIGURABLE SETTINGS | |||
Function | Location | Setting | |
» | Floppy drive enabled | JP2 | closed |
Floppy drive disabled | JP2 | open | |
» | SCSI Termination enabled | JPTP | closed |
SCSI Termination disabled | JPTP | open | |
» | I/O and BIOS Address is software configured | JP12/jumper 4 | open |
I/O and BIOS Address is jumper configured | JP12/jumper 4 | closed |
MISCELLANEOUS TECHNICAL NOTES |
* When JP12/jumper 4 is open (factory default), I/O and BIOS address is software configured. All other jumpers are factory configured - do not alter |