LOMAS DATA PRODUCTS, INC.
LDP CACHE IIP
Data bus: | 16-bit, ISA |
Size: | Full-length, full-height card |
Hard drive supported: | Up to seven SCSI devices |
Floppy drives supported: | Two 360KB, 720KB, 1.2MB, or 1.44MB drives |
CONNECTIONS | |
Function | Location |
34-pin control cable connector - floppy drive | J3 |
50-pin SCSI connector - internal | J4 |
25-pin SCSI II connector - external (optional feature) | J5 |
20-pin factory test connector - internal | J6 |
12-pin connector - Drive active LED | J7/pins 1 & 2 |
12-pin connector - Error LED | J7/pins 3 & 4 |
USER CONFIGURABLE SETTINGS | |||
Function | Location | Setting | |
» | LED operational when hard drive is active | J7 | pins 9 & 10 closed |
LED operational when controller is active | J7 | pins 9 & 10 open | |
» | Error LED status software interrogation enabled | J7 | pins 11 & 12 open |
Error LED status software interrogation disabled | J7 | pins 11 & 12 closed | |
» | 1x9 SIMM module configuration enabled | JP1 & JP2 | pins 1 & 2 closed |
4x9 SIMM module configuration enabled | JP1 & JP2 | pins 2 & 3 closed | |
» | Floppy drive enabled | JP7 | closed |
Floppy drive disabled | JP7 | open | |
» | Controller supplies TERMPWR to SCSI interface 26 | JP8 | closed |
TERMPWR not supplied to SCSI Interface 26 | JP8 | open | |
» | BIOS enabled | JP9 | closed |
BIOS disabled | JP9 | open | |
» | I/O port address is 320h (primary) | JP12 & JP13 | closed |
I/O port address is 324h (secondary) | JP12 & JP13 | open |
BIOS ADDRESS | |||
Address | Jumper JP10 | Jumper JP11 | |
» | C800h | closed | closed |
D000h | closed | open | |
D800h | open | closed |
INTERRUPT REQUEST | |||
IRQ | JP14/Jumper 1 | JP14/Jumper 2 | |
» | 14 | closed | open |
15 | open | closed |
MISCELLANEOUS TECHNICAL NOTES |
All other jumpers are factory configured -- do not alter. If secondary I/O port address is enabled, configure JP14 to Jumper 1 open, Jumper 2 closed -- IRQ15 enabled. |