INFORTREND TECHNOLOGY, INC.
IFT-2000A
Data bus: | 32-bit PCI |
Size: | Three-quarter length, full-height card |
Hard drive supported: | Up to seven Fast SCSI-2 devices |
Floppy drives supported: | None |
CONNECTIONS | |
Function | Location |
4-pin connector - drive active LED | JP2 |
50-pin SCSI connector - internal channel 0 | JP4 |
50-pin SCSI connector - external channel 0 | JP17 |
9-pin serial port - external | JP20 |
USER CONFIGURABLE SETTINGS | |||
Function | Location | Setting | |
» | Factory configured - do not alter | JP1 | pins 1 & 2 closed |
» | Factory configured - do not alter | JP10 | open |
» | Factory configured - do not alter | JP11 | open |
» | Factory configured - do not alter | JP15 | open |
ONBOARD CPU SELECTION | ||
CPU | JP9 | JP18 |
486SX-25 | pins 1 & 2 closed | pins 2 & 3 closed |
486DX-25 | pins 1 & 2 closed | pins 1 & 2, 3 & 4 closed |
486SX-33 | pins 2 & 3 closed | pins 2 & 3 closed |
486DX-33 | pins 2 & 3 closed | pins 1 & 2, 3 & 4 closed |
DRAM CONFIGURATIONS | |
Size | Bank 0 |
2 MBytes | (1) 512K x 36 |
4 MBytes | (1) 1M x 36 |
8 MBytes | (1) 2M x 36 |
16 MBytes | (1) 4M x 36 |
32 MBytes | (1) 8M x 36 |
Note: Minimum of 2 MBytes DRAM must be installed with/without parity function. Minimum of 4 MBytes DRAM suggested for RAID-3 and RAID-5 configurations. |
MISCELLANEOUS NOTES |
Pin 1 for jumpers JP1, JP9, JP18 are designated for diagram purposes only. |