GVC TECHNOLOGIES, INC.
NIC-1000T
NIC Type | Ethernet |
Transfer Rate | 10Mbps |
Data Bus | 8-bit ISA |
Topology | Star |
Wiring Type | Shielded/Unshielded twisted pair AUI transceiver via DB-15 port |
Boot ROM | Available |
BOOT ROM | ||
Setting | W1 | |
» | Disabled | Open |
Enabled | Closed |
I/O BASE ADDRESS AND BOOT ROM ADDRESS | ||||
I/O Address | Boot ROM Address | W2 | W3 | |
» | 300-31Fh | C8000-CBFFFh | Closed | Closed |
320-33Fh | CC000-CFFFFh | Open | Closed | |
340-35Fh | D0000-D3FFFh | Closed | Open | |
360-37Fh | D4000-D7FFFh | Open | Open |
INTERRUPT REQUEST | |||||
IRQ | W4 | W5 | W6 | W7 | |
2 | Open | Open | Open | Closed | |
» | 3 | Closed | Open | Open | Open |
4 | Open | Closed | Open | Open | |
5 | Open | Open | Closed | Open |
CABLE TYPE | ||
Type | W8 | |
» | Shielded/Unshielded twisted pair | Pins 2 & 3 closed |
AUI transceiver via DB-15 port | Pins 1 & 2 closed |
LINK INTEGRITY TEST | ||
Setting | W9 | |
» | Enabled | Pins 1 & 2 closed |
Disabled | Pins 2 & 3 closed |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
LED1 | Green | On | Twisted pair network connection is good |
LED1 | Green | Off | Twisted pair network connection is broken |
LED2 | Red | On | Polarity is correct |
LED2 | Red | Off | Polarity is reversed and corrected |
LED3 | Yellow | Blinking | Data is being transmitted |
LED3 | Yellow | On | Data is not being transmitted |
LED3 | Yellow | Off | Card is not receiving power or is malfuntioning |
LED4 | Red | Blinking | Data is being received |
LED4 | Red | On | Data is not being received |
LED4 | Red | Off | Card is not receiving power or is malfuntioning |
Note:When Link Integrity is disabled, LED1 will remain off. This does not indicate a faulty connection. |