GARRETT COMMUNICATIONS
MAGNUM TP1
Card Type | Ethernet Transceiver |
NIC Type | Ethernet |
Maximum Onboard Memory | Unidentified |
Boot ROM | Not available |
Network Transfer Rate | 10Mbps |
Topology | Linear Bus, Star |
Wiring Type | Shielded twisted pair, Unshielded twisted pair AUI transceiver via DB-15 port |
Data Bus | External |
CONNECTIONS | |||
Function | Label | Function | Label |
AUI transceiver via DB-15 | CN1 | UTP/STP connector (RJ-45) | CN2 |
USER CONFIGURABLE SETTINGS | |||
Function | Label | Position | |
» | Automatic correction for reversed polarity enabled | SW1 | On |
Automatic correction for reversed polarity disabled | SW1 | Off | |
» | Unshielded twisted pair | SW2 | Off |
Shielded twisted pair | SW2 | On | |
» | 10BASE-T enabled | SW3 | On |
Starlan 10 (ATT) polarity on the segment | SW3 | Off | |
» | SQE enabled | SW4 | On |
SQE disabled | SW4 | Off |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
LED1 | Green | On | Network connection established |
LED1 | Green | Off | Network connection is not established |
LED2 | Yellow | On | Collision has occurred |
LED2 | Yellow | Off | Collision has not occurred |
LED3 | Green | Blinking | Data is being received |
LED3 | Green | Off | Data is not being received |
LED4 | Green | On | Data is being transmitted |
LED4 | Green | Off | Data is not being transmitted |
LED5 | Yellow | On | Polarity error |
LED5 | Yellow | Off | No polarity error |
LED6 | Yellow | On | SQE test feature enabled |
LED6 | Yellow | Off | SQE test feature disabled |
LED7 | Green | On | Power is on |
LED7 | Green | Off | Power is off |
MISCELLANEOUS TECHNICAL NOTES |
The AUI port should be directly connected to the workstation. If you cannot connect to the workstation, an AUI drop cable (which cannot exceed 3 feet in length) may be used. |