DIGITAL EQUIPMENT CORPORATION
DEC EtherWORKS LC/TP
NIC Type | Ethernet |
Transfer Rate | 10Mbps |
Data Bus | 8-bit ISA |
Topology | Star |
Wiring Type | Shielded/Unshielded twisted pair AUI transceiver via DB-15 port |
Boot ROM | Available |
CABLE TYPE | ||
Type | JP1A - JP2G | |
» | Shielded/Unshielded twisted pair | Pins 2 & 3 Closed |
AUI transceiver via DB-15 port | Pins 1 & 2 Closed |
BASE MEMORY ADDRESS | ||||||
Address | Buffer Size | SW1/1 | SW1/2 | SW1/3 | SW1/4 | |
C0000-CFFFFh | 64KB | Off | On | On | On | |
C8000-CFFFFh | 32KB | Off | On | Off | On | |
» | D0000-DFFFFh | 64KB | On | On | On | On |
D8000-DFFFFh | 32KB | On | On | Off | On | |
E0000-EFFFFh | 64KB | Off | Off | On | On | |
E8000-EFFFFh | 32KB | Off | Off | Off | On |
I/O BASE ADDRESS | ||
Address | SW1/5 | |
» | 300 - 30Fh | On |
200 - 20Fh | Off |
BOOT ROM | ||
Setting | SW1/6 | |
» | Disabled | On |
Enabled | Off |
BOOT ROM TIMEOUT | ||
Setting | SW1/7 | |
» | Boot ROM timeout select 30 seconds | Off |
Boot ROM timeout select 150 seconds | On |
INTERRUPT REQUEST | ||||||
IRQ | SW1/8 | SW1/9 | SW1/10 | SW1/11 | SW1/12 | |
» | 5 | On | Off | Off | Off | Off |
9 | Off | On | Off | Off | Off | |
10 | Off | Off | On | Off | Off | |
11 | Off | Off | Off | On | Off | |
15 | Off | Off | Off | Off | On |
DIAGNOSTIC LED(S) | ||
Color | Status | Condition |
Amber | On for 20 sec., then off | Card is performing a self-test |
Amber | On | Fault has occurred, displays error code on screen. |
Green | Blinking | Data is being received |
Green | Off | Data is not being received |