COMPU-SHACK PRODUCTION, GMBH
CS-ARCNET-KARTE (REV. 3.31/3.31S)
NIC Type: | ARCnet |
Transfer Rate: | 2.5Mbps |
Data Bus: | 8-bit ISA |
Topology: | Linear Bus |
Wiring Type | RG62A/U 93ohm coaxial |
Boot ROM | Available |
INTERRUPT SELECT - J2 | ||||||
IRQ | Jumper A | Jumper B | Jumper D | Jumper D | Jumper E | |
» | IRQ2 | Closed | Open | Open | Open | Open |
IRQ3 | Open | Closed | Open | Open | Open | |
IRQ4 | Open | Open | Closed | Open | Open | |
IRQ5 | Open | Open | Open | Closed | Open | |
IRQ7 | Open | Open | Open | Open | Closed |
RESPONSE TIME-OUTS | |||
Response Time | J4/jumper A | J4/jumper B | |
» | 74.7µs | Open | Open |
283.4µs | Closed | Open | |
561.8µs | Open | Closed | |
1118.6µs | Closed | Closed |
I/O ADDRESS | ||||||
Address | S1/1 | S1/2 | S1/3 | S1/4 | S1/5 | S1/6 |
2E0h | Off | On | Off | Off | Off | On |
200h | Off | On | On | On | On | On |
210h | Off | On | On | On | On | Off |
220h | Off | On | On | On | Off | On |
I/O ADDRESS | ||||||
Address | S1/1 | S1/2 | S1/3 | S1/4 | S1/5 | S1/6 |
230h | Off | On | On | On | Off | Off |
240h | Off | On | On | Off | On | On |
250h | Off | On | On | Off | On | Off |
260h | Off | On | On | Off | Off | On |
270h | Off | On | On | Off | Off | Off |
280h | Off | On | Off | On | On | On |
290h | Off | On | Off | On | On | Off |
2A0h | Off | On | Off | On | Off | On |
2B0h | Off | On | Off | On | Off | Off |
2C0h | Off | On | Off | Off | On | On |
2D0h | Off | On | Off | Off | On | Off |
2F0h | Off | On | Off | Off | Off | Off |
300h | Off | Off | On | On | On | On |
310h | Off | Off | On | On | On | Off |
320h | Off | Off | On | On | Off | On |
330h | Off | Off | On | On | Off | Off |
340h | Off | Off | On | Off | On | On |
350h | Off | Off | On | Off | On | Off |
360h | Off | Off | On | Off | Off | On |
370h | Off | Off | On | Off | Off | Off |
380h | Off | Off | Off | On | On | On |
390h | Off | Off | Off | On | On | Off |
3A0h | Off | Off | Off | On | Off | On |
3B0h | Off | Off | Off | On | Off | Off |
3C0h | Off | Off | Off | Off | On | On |
3D0h | Off | Off | Off | Off | On | Off |
3E0h | Off | Off | Off | Off | Off | On |
3F0h | Off | Off | Off | Off | Off | Off |
MEMORY ADDRESS | ||||
Address | S1/7 | S1/8 | S1/9 | S1/10 |
C0000h | Off | Off | On | On |
D0000h | Off | Off | On | Off |
E0000h | Off | Off | Off | On |
NODE ID NUMBER | ||||||||
ID # | S2/1 | S2/2 | S2/3 | S2/4 | S2/5 | S2/6 | S2/7 | S2/8 |
1 | On | Off | Off | Off | Off | Off | Off | Off |
255 | On | On | On | On | On | On | On | On |
Note:Nodes can be numbered from 1 to 255. The switches are a binary representation of the node numbers. When a switch is on, the corresponding bit is set to 1 and has the following decimal value: S2/1=1, S2/2=2, S2/3=4, S2/4=8, S2/5=16, S2/6=32, S2/7=64, S2/8=128. |
DIAGNOSTIC LED | |
Status | Condition |
On | Data is being transmitted or received |
Off | Data is not being transmitted or received |