CODENOLL TECHNOLOGY CORPORATION
CODENET-8380, CODENET-8382
Card Type | Ethernet transceiver |
Network Transfer Rate | 10Mbps |
Data Bus | AUI via DB-15 connector |
Topology | Star |
Wire Type | Fiber optic cable |

CONNECTIONS | |||
Function | Label | Function | Label |
AUI via DB-15 port | CN1 | Fiber receive connector | CN3 |
Fiber transmit connector | CN2 | ||
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
| » | Link good function enabled | SW1/1 | On |
Link good function disabled | SW1/1 | Off | |
| » | SQE heartbeat disabled | SW1/2 | On |
SQE heartbeat enabled | SW1/2 | Off | |
| » | Point-to-point mode | SW1/3 | On |
Passive star mode | SW1/3 | Off | |
| » | Jabber lockout resets automatically | SW1/4 | On |
Jabber lockout resets only by cycling power | SW1/4 | Off | |
| » | Optical transmitter at full power | SW1/5 | Off |
Optical transmitter at half power for testing | SW1/5 | On | |
| » | Factory configured - do not alter | SW1/6 | N/A |
| » | Factory configured - do not alter | SW1/7 | N/A |
| » | Factory configured - do not alter | SW1/8 | N/A |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
JABBER | Yellow | On | Network jabber detected |
JABBER | Yellow | Off | Network jabber not detected |
HIGH | Yellow | On | Received optical signal too bright |
HIGH | Yellow | Off | Received optical signal normal |
LINK | Yellow | On | Network connection is broken |
LINK | Yellow | Off | Network connection is good |
CP | Yellow | On | Network collision detected |
CP | Yellow | Off | Network collision not detected |
ACT | Green | On | Transceiver is receiving or transmitting to the network |
ACT | Green | Off | Transceiver is not receiving or transmitting to the network |
POWER | Green | On | Power is on |
POWER | Green | Off | Power is off |