D 5 6 5 5 NEC Native| Translation ------+-----+-----+----- Form 5.25"/HH Cylinders 1224| | | Capacity form/unform 147/ MB Heads 7| | | Seek time / track 18.0/ ms Sector/track | | | Controller ESDI Precompensation Cache/Buffer KB Landing Zone Data transfer rate 1.250 MB/S int Bytes/Sector 512 MB/S ext Recording method RLL 2/7 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C | Power: sleep W Humidity % | standby W Altitude km | idle W Shock g | seek W Rotation RPM read/write W Acoustic dBA spin-up W ECC Bit MTBF h 30000 Warranty Month Lift/Lock/Park YES Certificates
NEC D5652/5655/5662/5682 INSTALLATION GUIDE
+------------------------------------------------------+ | |XX | PWA |XX J2 | |XX | |XX | | | | | +++++++++ +++++ |XX | ++++++++++ ++++++ |XX | DIP Switches ----+ |+++++ |XX J1 | for Drive Address++++++++++ ++++++ |XX | and Optional +++++++++ |+++++ |XX | Functions ++++++ |XX | DIP Switches|XX | Terminating | | Resistors |XX J3 | |XX Power +------------------------------------------------------+
NEC D5652/5655/5662 INSTALLATION GUIDE
Jumper Setting
==============
D5652/D5655/D5662
-----------------
Drive Selection = 7.
DS MODE +-3-2-1-P-S-B-A-M-+ 1 | o o x o x o o o | Drive 1, Hard Sector Mode 0 | x x o x o x x x | +-----------------+
DS MODE +-3-2-1-P-S-B-A-M-+ 1 | o x o o x o o o | Drive 2, Hard Sector Mode 0 | x o x x o x x x | +-----------------+
S - COUNT +-C-6-5-4-3-2-1-0-+ 1 | x o x o o x o o | 36 Sectors/Track 0 | o x o x x o x x | +-----------------+
Recommended configuration is: drive #1 or #2 36 sectors/track.
NEC D5652/5655/5662/5682 INSTALLATION GUIDE
Installation
------------
- select Type 1
- select spare sector option
- start format under DEBUG G=C800:5 with spare sector
D5662/D5655
-----------
Use translation mode with 60 or 63 sectors per track after the low
level format.
D5655
-----
When you are using the NCL controller and NOVELL, select under DEBUG
the ROM-BIOS table type 77.
Debug address for the WD 1007V controller is G=CC00:5.
D5662
-----
When you are using the NCL controller and NOVELL, select under DEBUG
the ROM-BIOS table type 98.
Debug address for the WD 1007V controller is G=CC00:5.
D5682
-----
When you are using the NCL controller and NOVELL, select under DEBUG
the ROM-BIOS table type 109.