4 4 2 1 A V MICROPOLIS
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 4050| | |
Capacity form/unform 2050/ MB Heads 7| | |
Seek time / track 8.8/ 1.1 ms Sector/track | | |
Controller SCSI2 SI/FAST/AV Precompensation
Cache/Buffer KB Landing Zone
Data transfer rate 7.200 MB/S int Bytes/Sector 512
10.000 MB/S ext SYNC
Recording method PRML operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 50 | -40 65
Power: sleep W Humidity % |
standby W Altitude km |
idle 7.5 W Shock g 10 | 60
seek 8.2 W Rotation RPM 5400
read/write W Acoustic dBA 37
spin-up W ECC Bit 126BIT REED SOLOMON,ON THE...
MTBF h 650000
Warranty Month 60
Lift/Lock/Park YES Certificates AV PERFORMANCE ENHAN,ISO9000
MICROPL. 4421AV JUMPER SETTING
+---------------------------------------------------------+ | |XX | |XX XX Component Side |XX XX Option Board No. 134302 |XX XX Jumper |XX J1 XX Block |XX XX J2 |XX XX |XX | 1 |XX | |XX ++ |XX ++LED |XX | |XX | |XX1 | |XX | |XX J1A | |XX +---------------------------------------------------------+ 1
MICROPL. 4421 AV JUMPER SETTING
Jumper Setting
==============
x = Factory default
Option Jumper Block
-------------------
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
LED+-+ - |27|25|23|21|19|17|15|13|11|09|07|05|03|01|
---+-+-----+ | | | | | | | | | | | | | +-------
+ |28|26|24|22|20|18|16|14|12|10|08|06|04|02|
++-++-++-++-++-++-++-++-++-++-++-++-++-++-+
RESERVED --+ | | | | | | | | | | | | +-- Remote LED
W4 -----+ | | | | | | | | | | +----- ID0
W3 --------+ | | | | | | | | +-------- ID1
W2 -----------+ | | | | | | +----------- ID2
W1 --------------+ | | | | +-------------- RESERVED
PTY -----------------+ | | +----------------- SP0
WP --------------------+ +-------------------- SP1
Single-Ended Configuration Options
----------------------------------
SCSI ID ------- +----------+-----------------------+ Up to eight devices (the host | SCSI ID | Jumpers | and seven targets) can be | | ID2 | ID1 | ID0 | attached to the SCSI Bus. +----------+-------+-------+-------+ | 0 | OPEN | OPEN | OPEN | ID jumpers ID0, ID1 and ID2 | 1 | OPEN | OPEN | CLOSED| are used to assign one of | 2 | OPEN | CLOSED| OPEN | eight SCSI ID bits (0-7) to | 3 | OPEN | CLOSED| CLOSED| the drive. | 4 | CLOSED| OPEN | OPEN | | 5 | CLOSED| OPEN | CLOSED| In multiple-device systems, | 6 | CLOSED| CLOSED| OPEN | each drive must have its own | x 7 | CLOSED| CLOSED| CLOSED| unique ID. +----------+-------+-------+-------+
SP0/SP1 Spindle Control Option
-------------------------------
SP0 CLOSED
SP1 OPEN Spindle motor starts when START UNIT command is
received.
SP0 OPEN (default)
SP1 OPEN Spindle motor starts at power-on.
SP0/SP1 Spindle Delay Option
-----------------------------
SP1 CLOSED
SP0 OPEN Spindle start-up is delayed based on SCSI ID (12
seconds per ID).
SP1 OPEN (default)
SP0 OPEN Spindle motor starts at power on.
WP Write Protect Option
------------------------
WP CLOSED Drive is write protected.
WP OPEN Drive is not write protected. (default)
PTY Bus Parity Check Option
----------------------------
PTY CLOSED Drive neither generates nor detects parity.
OPEN Drive generates parity and has parity detection
enabled. (default)
W1/W2/W3 Bus Termination Power Option
--------------------------------------
W1 CLOSED (default)
Drive provides terminator power.
W2 CLOSED
Host system provides terminator power (via J1).
W3 CLOSED
Drive provides terminator power (via J1) to the BUS.
W4 Interface Termination
------------------------
W4 INSTALLED Drive provides termination for the interface lines;
i.e., onboard termination is electrically enabled.
x OMITTED Drive does not provide terminatiopn for the inter-
face lines; i.e., onboard termination is
electrically disabled.
Remote LED
----------
Open Collector output - Used to drive a user-supplied LED to indicate
the drive is active.
AV
What is an AV Drive?
--------------------
Today's demanding digital video and audio applications require disk
drives to sustain a pre-determined minimum data transfer rate.
Any interruptions in this data rate are detrimental to AV
applications that require constant delivery of data at 30 frames per
second minimum. In standard drives utilized for data processing
requirements, the error correction and thermal calibration methods
employed are not optimized for continuous delivery of data. These
routine housekeeping tasks will procedure gaps in the data stream as
long as 850 ms, resulting in jumps, gaps, and stutters in motion and
sound when used in most AV applications.
(MICROPOLIS 10/96)