4 2 2 1 D MICROPOLIS
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 4160| | |
Capacity form/unform 2147/ MB Heads 9| | |
Seek time / track 8.5/ 1.3 ms Sector/track | | |
Controller SCSI2 DI/FAST Precompensation
Cache/Buffer 512 KB SEGMENTED Landing Zone
Data transfer rate MB/S int Bytes/Sector 512
10.000 MB/S ext SYNC
Recording method RLL operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 50 | -40 65
Power: sleep W Humidity % |
standby W Altitude km |
idle 10.3 W Shock g 10 | 60
seek 11.5 W Rotation RPM 7200
read/write W Acoustic dBA 36
spin-up W ECC Bit 126,REED SOLOMON
MTBF h 1000000
Warranty Month 60
Lift/Lock/Park YES Certificates FM21571,ISO9000
MICROPL. 4221/4210 TAURUS 2 PRODUCT DESCRIPTION 110791 REV.A 1994
+---------------------------------------------------------+ | |XX +--+ ++|XX | | |||XX | | |||XX | |Option W3-Termination |||XX | |Jumper +-+Power |||XX | |Block Not used+++ID2 RN2||XX | | ++++ ++|XX +--1 RN1||XX | |||XX | |||XX | |||XX ++LED ID0++ID1 |||XX ++ ++++ ++|XX1 J1 | | | |XX |COMPONENT SIDE NO. 136602 SINGLE-ENDED |XX1 J1A +---------------------------------------------------------+
MICROPL. 4221/4210 TAURUS 2 PRODUCT DESCRIPTION 110791 REV. A 1994
Jumper Setting
==============
x = Factory default
Option Jumper Block
-------------------
+--+--+--+--+--+--+--+--+--+--+--+--+--+--+
- |27|25|23|21|19|17|15|13|11|09|07|05|03|01|
-----------+ | | | | | | | | | | | | | +-------
+ |28|26|24|22|20|18|16|14|12|10|08|06|04|02|
++-++-++-++-++-++-++-++-++-++-++-++-++-++-+
RESERVED --+ | | | | | | | | | | | | +-- Remote LED
Key 2 NC -----+ | | | | | | | | | | +----- ID0
SSYNC --------+ | | | | | | | | +-------- ID1
MSYNC -----------+ | | | | | | +----------- ID2
Key 1 NC --------------+ | | | | +-------------- RESERVED
PTY -----------------+ | | +----------------- SP0
WP --------------------+ +-------------------- SP1
Single-Ended Configuration Options
----------------------------------
SCSI ID
-------
NOTE:
There are two identical groups of address jumpers on the Device
Electronics board; use either group for address selection but not
both at the same time.
+----------+-----------------------+ Up to eight devices (the host | SCSI ID | Jumpers | and seven targets) can be | | ID2 | ID1 | ID0 | attached to the SCSI Bus. +----------+-------+-------+-------+ | 0 | OPEN | OPEN | OPEN | ID jumpers ID0, ID1 and ID2 | 1 | OPEN | OPEN | CLOSED| are used to assign one of | 2 | OPEN | CLOSED| OPEN | eight SCSI ID bits (0-7) to | 3 | OPEN | CLOSED| CLOSED| the drive. | 4 | CLOSED| OPEN | OPEN | | 5 | CLOSED| OPEN | CLOSED| In multiple-device systems, | 6 | CLOSED| CLOSED| OPEN | each drive must have its own | x 7 | CLOSED| CLOSED| CLOSED| unique ID. +----------+-------+-------+-------+
Interface Termination
---------------------
Terminators installed at RN1 and RN2 (default)
Drive provides termination for the interface lines.
Terminators at RN1 and RN2 omitted
Drive does not provide termination for the interface lines.
SP0/SP1 Spindle Control Option
-------------------------------
SP0 CLOSED
SP1 OPEN Spindle motor starts when START UNIT command is
received.
SP0 OPEN (default)
SP1 OPEN Spindle motor starts at power-on.
SP0/SP1 Spindle Delay Option
-----------------------------
SP1 CLOSED
SP0 OPEN Spindle start-up is delayed based on SCSI ID (12
seconds per ID).
SP1 OPEN (default)
SP0 OPEN Spindle motor starts at power on.
WP Write Protect Option
------------------------
WP CLOSED Drive is write protected.
WP OPEN Drive is not write protected. (default)
PTY Bus Parity Check Option
----------------------------
PTY CLOSED Drive neither generates nor detects parity.
OPEN Drive generates parity and has parity detection
enabled. (default)
W1/W2/W3 Bus Termination Power Option
--------------------------------------
+-----+ +-----+ +-----+
W3 xxx | | o X W2 | o o |
| o o | | o X | | xxx W1
+-----+ +-----+ +-----+
W1 CLOSED (default)
Drive provides local terminator power.
W2 CLOSED
Host system provides local terminator power.
W1 CLOSED and W3 CLOSED
Drive provides terminator local power and terminator power to the
bus.
Remote LED Option
-----------------
LED (user supplied) connected to Remote LED
Both LEDs (on Device Electronics board and remote location) are
enabled.
Remote LED not connected (default)
LED on Device Electronics board enabled.
Spindle Synchronization
-----------------------
The Rotational Position Locking field (MODE SELECT command, Page Code
04h) is used to specify spindle synchronization operation.
Unsynchronized: If the drive is set to Unsynchronized (RPL = 00b), it
ignores the SLAVE SYNC signal.
Slave: If the drive is set to Slave (RPL = 01b), it does not generate
the MASTER SYNC signal or the SLAVE SYNC signal but synchronizes its
index to the SLAVE SYNC signal supplied by an external source. Signal
termination is placed on the SLAVE SYNC signal at the first and the
last device in the chain only.
Master: If the drive is set to Master (RPL = 10b), it generates the
SLAVE SYNC output signal for use directly by the slave drives. Signal
termination is placed on the SLAVE SYNC signal at the first and the
last device in the chain only.
Master Control: If the drive is set to Master Control (RPL = 11b), it
generates the MASTER SYNC signal. This output is used by the
controller to generate the SLAVE SYNC signal for the slaves. Signal
termination is placed on the SLAVE SYNC signal at the first and the
last device in the chain only.