1 3 5 3 MICROPOLIS NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 5.25"/FH Cylinders 1024| | | Capacity form/unform 75/ 85 MB Heads 4| | | Seek time / track 23.0/ 5.0 ms Sector/track 36| | | Controller ESDI Precompensation Cache/Buffer KB Landing Zone Data transfer rate 1.250 MB/S int Bytes/Sector 512 MB/S ext Recording method RLL 2/7 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 10 50 | -40 65 Power: sleep W Humidity % 10 90 | 10 90 standby 29.0 W Altitude km -0.061 3.048| -0.305 15.240 idle W Shock g 3 | 50 seek 35.0 W Rotation RPM 3600 read/write W Acoustic dBA 51 spin-up W ECC Bit MTBF h 30000 Warranty Month Lift/Lock/Park YES Certificates
MICROPL. 1350 SERIES PRODUCT DESCRIPTION 103551 REV. B
+---------------------------------------------------------+ | | | Interface +--+ |X1 J1 | COMPONENT SIDE Terminator | |RN1|XX | | | |XX | +--+ |XX | |XX | |XX | DA3+-+ |XX | DA2| | | | DA1| | |X1 | W5 | | |XX J2 | W4 | | |XX | W3 | | |XX | W2 +-+ |XX | W1 |XX | | +---------------------------------------------------------+
+--------------------------------------+ | ++J4 | | ++ | | ++J5 | | J3 Power++ | | XXXXXX1 | | J2 J1 | | XXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXX | +--------------1--------------------1--+ Data Transfer Control Signal
MICROPL. 1350 SERIES PRODUCT DESCRIPTION 103551 REV. B
Jumper setting
==============
x = Jumper set at factory
Drive Select DA3/DA2/DA1 ------------------------- +--------+------------------------+ |Drive | Select Jumpers | |Address | DA3 DA2 DA1 | +--------+------------------------+ |x 1 | OPEN OPEN CLOSED | +--------+------------------------+ | 2 | OPEN CLOSED OPEN | +--------+------------------------+ | 3 | OPEN CLOSED CLOSED | +--------+------------------------+ | 4 | CLOSED OPEN OPEN | +--------+------------------------+ | 5 | CLOSED OPEN CLOSED | +--------+------------------------+ | 6 | CLOSED CLOSED OPEN | +--------+------------------------+ | 7 | CLOSED CLOSED CLOSED | +--------+------------------------+
"Drive Address 0" is used as a "deselect" (i.e., no drive is
selected).
The three Drive Select interface lines are decoded to select the
correspondingly addressed drive to the host controller/formatter. In
multiple-drive systems, each drive must have its own unique address.
Terminator Pack RN1 provides proper termination for the interface
lines. When daisy-chaining multiple 1350 drives, the terminator is
installed only in the last drive on the daisy chain.
W1 Hard- or Soft-sectored mode ------------------------------- CLOSED The drive is configured to operate in the SOFT-SECTORED mode. Address mark generation and detection are enabled, and the Sector/Address Mark Found interface signal is used to report address mark found. Sector size is selected by the host controller. OPEN The drive is configured to operate in the HARD-SECTORED mode. The Sector/Address Mark Found interface signal is used to transmit sector pulses to the host controller. (Factory default)
Sector pulses are derived from the servo disk. The number of sector pulses generated is equal to: + + |20,832| Where 20,832 = byte clock derived from servo INT|------| disk | n | INT = integer part of + + n = the number of bytes/sector (82 minimum)
W2/W3/W4 Hard Sector Configuration ----------------------------------- +--------+---------------------------+------------------------+ |Sectors | Bytes/Sector | Jumpers | | | Formatted Unformatted | W4 W3 W2 | +--------+---------------------------+------------------------+ | 35 | 512 595 | OPEN OPEN OPEN | +--------+---------------------------+------------------------+ | 36 | 512 578 | OPEN OPEN CLOSED| +--------+---------------------------+------------------------+ | 19 | 1024 1096 | OPEN CLOSED OPEN | +--------+---------------------------+------------------------+ | 9 | 2048 2314 | OPEN CLOSED CLOSED| +--------+---------------------------+------------------------+ | 5 | 4096 4166 | CLOSED OPEN OPEN | +--------+---------------------------+------------------------+ | 32 | 512 651 | CLOSED OPEN CLOSED| +--------+---------------------------+------------------------+ | 64 | 256 325 | CLOSED CLOSED OPEN | +--------+---------------------------+------------------------+ | 1 | 20832 20832 | CLOSED CLOSED CLOSED| +--------+---------------------------+------------------------+
The number of bytes/sector may be specified using the Set Bytes Per
Sector command or by selecting a default sector configuration with
option jumpers W2, W3, and W4.
W5 Spindle Control Option -------------------------- CLOSED The drive must wait for a Start Spindle command to start the spindle motor. OPEN The drive automatically starts the spindle motor at power-on. (Factory default configuration)
J3 DC Power and pin connector assignments ------------------------------------------- +------------+ pin 1 +12 VDC | 4 3 2 1 | pin 2 +12 Return +------------+ pin 3 + 5 Return pin 4 + 5 VDC
J4/J5 Ground Connectors
------------------------
1/4-inch spade lugs J4 and J5 are provided for grounding.
MICROPL. 1350 SERIES PRODUCT DESCRIPTION 103551 REV. B
Notes on installation
=====================
Drive mounting
--------------
horizontally vertically +-----------------+ +--+ +--+ +------------------+ | | | +-----+ +-----+ | | | x | | | | | | | | x+----------------+x +-+-----------------+-+ | | | | | | ||x x|| +---------------------+ | | | | | | || x x || | | | | | | || x x || x x | | | | | | || x x || +------x------x-------+ | +-----+ +-----+ | || xx || +-+------x--x-------+-+ +--+ +--+ || x x || | xx | || x x || | x x | || x x || +---x--------x----+ |x x| x x x++----------------++x
Dimensions and Mounting
-----------------------
Recommended orientation is vertical on either side, or horizontal
with the Device Electronics board down; other mounting orientations
may be used provided the ambient air temperature around the drive is
kept at or below 46*C (115*F).
In as much as the frame of the drive acts as a heat sink to
dissipate heat from the unit, the enclosure and mounting structure
should be designed to allow natural convection of heat around the HDA
and outer frame. If the enclosure is small or natural convetion is
restricted, a fan may be required.
The 1350 Series uses industry-standard mounting 5 -inch Winchester
disk drives (the same as for 5 -inch flexible disk drives).
Mounting Screws
---------------
2 per side 6-32 UNC-2B x 0.25 deep.
4 on bottom 6-32 UNC-2B x 0.25 deep.
The length of the mounting screws must be such that the screws do not
penetrate the mounting holes by more than 0.25 inch. Maximum torque
applied to the screws must not exceed 10 in-lbs.
Control Signal Connector J1
---------------------------
J1 is a 34-pin board-edge connector on the Device Electronics board.
The signals on this connector control the drive and transfer drive
status to the host controller.
Recommended Cable: 3M Scotchflex 3365/34 Mating Connector: 3M Scotchflex 3463-0001 (key slot between pins 4 and 6)
Data Transfer Connector J2
--------------------------
J2 is a 20-pin board-edge connector on the Device Electronics board.
The signals on this connector contain read or write data.
Recommended Cable: 3M Scotchflex 3365/20 Mating Connector: 3M Scotchflex 3461-0001 (key slot between pins 4 and 6)
DC Power Connector J3 --------------------- J3 is a 4-pin, keyed AMP MATE-N-LOCK Connector on the Motor Control board. DC power (+5V and +12V) is supplied to the drive via this connector.
Mating Connector: AMP 1-480424-0 Pins: AMP 350078-4
Suggested Wire Size: 18 AWG
Ground Connectors J4/J5
-----------------------
1/4-inch spade lugs J4 and J5 are provided for grounding; system
characteristics determine the proper ground connection.
Mating Connector: AMP 62187-1 or equivalent.
Daisy-Chaining the 1350 Drive
------------------------------
+-HOST-------+ +---------------+ | CONTROLLER +--CONTROL---o-----+ J1 Drive #1 | | | +DATA-----+-----+ J2 | | | | | +--+ J3 J4/J5 | | | | | | +-------+-------+ | | | | | +-------------+ | | | | | +---------------+ | | | | o--+--+ J1 Drive #2 | | | | | +DATA--+--+--+ J2 | | | | | | | o--+ J3 J4/J5 | | | | | | | | +-------+-------+ | | | | | | | +-------------o | | | | | | +---------------+ | | | | | o--+--+ J1 Drive #3 | | | | | | +--+--+--+ J2 | | |------------| | | | | o--+ J3 J4/J5 | | | | | | | | | +-------+-------+ | | +--+ | | | | +-------------o | DATA +-----+ | | | +---------------+ | | SEPARATOR +-DATA----+ +--+--+ J1 Drive #4 | | | +----DATA-------+--+ J2 +----+ | | | o--+ J3 J4/J5|RN1 | | +------------+ | +-------+--+----+ | | | | DC VOLTAGES -------------+ | | GROUND ------------------------o-------------+
Interface Terminator RN1 is installed ONLY in the last physical
drive in the control chain.
Up to seven 1350-Series drives may be connected to a single host
controller/formatter. Control signals at J1 are transmitted via
standard, daisy-chain interconnection. Data signals at J2 are
transmitted via radially connected data-transfer lines.
Interface Electrical Characteristics
------------------------------------
The signals at Control Signal Connector J1 control the drive and
transfer drive status to the host controller. The signals are low-
true at the interface, high-true into drivers and out of receivers,
and have the following logic levels:
True = 0.0 VDC to 0.4 VDC @ I = -48 milliamps (maximum) False = 2.5 VDC to 5.25 VDC @ I = +250 microamps (open collector)
All interface data transfer signals are differential in nature.
Up to seven drives can be connected to one host controller/formatter.
Drive Select 1, 2 and 3 carry the binary-coded addres of the drive to
be selected. The address of the drive is set with drive selection
jumpers DA1, DA2, and DA3 as a binary combination. When the address
is decoded and the decoded value matches the value specified by the
three drive-selection jumpers, that drive is enabled to receive
commands and transmit status. Drive Select 1 is the least significant
bit.
Adjustments and Maintenance
---------------------------
The 1350-series of drives requires no adjustments or periodic
maintenance. Additionally, no mechanical adjustments are required to
prepare the drives for handling or shipment.
Field-Replaceable Components
----------------------------
The concept of repair by replacement of complete functional
components is utilized in the 1350 Series, resulting in an MTTR of
less than 15 minutes.
Air-Filtration System
---------------------
Air is circulated throughout the clean area by disk rotation-induced
flow. A ducted air-filtration system draws the air through a filter.
The sealed area breathes to the outside via another filter for
pressure equalization.
Drive Motor
-----------
Spindle rotation s provided by a quiet, direct-coupled, brushless DC
motor. Switching information for the electronic commuator is supplied
by three Hall-effects sensors mounted within the drive-motor
assembly.
MICROPL. 1350 SERIES PRODUCT DESCRIPTION 103551 REV. B
Micropolis 1350 Series high-performance, 5 -inch Winchester Disk
Drives provide OEMs with high-speed, high-capacity, random-access
storage. They are fully compatible with the Serial mode of the
Enhanced Small Device Interface (ESDI) standard and are designed to
meet the needs of diverse applications environments.
Media Defects
-------------
Media defects are physical characteristics of the media which result
in repetitive read errors when a functional drive is operated within
specified operating conditions. A single defect is defined as being
less than two bytes long. A multiple defect is defined as two bytes
longer, or as a track with more than one single defect.
At the time of manufacture, a media test system evaluates each 1320
drive and identifies the location of each media defect. The defects
are logged on a label affixed to the drive. Defective areas are
identified by cylinder, head address, and number of Bytes from Index.
A printout (listing) of the defects is also shipped with each drive.
Micropolis specifies that all 1350 Series disk drives will have no
more than one defect per megabyte of unformatted capacity. Addition-
ally, Cylinder 0 shall be defect-free at the time of shipment.
Seek Time
---------
| 1350 | ----------------------------------+--------+ Track-to-Track msec. typ. | 5 | Average msec. typ. | 23 | One-Third Stroke msec. | 25 | msec. max. | 50 | Latency msec. avg. | 8.33 | Nominal msec. max. | 16.67 | ----------------------------------+--------+