Articles / TULARC / PC info / Hard Drives / HITACHI Hard Drives / | ![]() |
|
![]() |
||||
![]() |
![]() |
|||
![]() |
![]() |
|||
![]() |
||||
|
|
||||
![]() |
![]() |
|||
![]() |
Hard Drive: HITACHI: DK514C-38 321MB 5.25"/FH SCSI1 SE |
![]() |
||
![]() |
||||
![]() |
![]() |
![]() |
||
![]() |
||||
![]() |
![]() |
![]() |
![]() |
||
![]() |
||
![]() |
![]() |
![]() |
![]() |
||
|
|
||
![]() |
||
![]() |
![]() |
![]() |
![]() |
||
![]() |
||
D K 5 1 4 C - 3 8 HITACHI
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 5.25"/FH Cylinders 903| | |
Capacity form/unform 321/ MB Heads 14| | |
Seek time / track 16.0/ 4.0 ms Sector/track 51| | |
Controller SCSI1 SINGLE-ENDED Precompensation
Cache/Buffer 24 KB FIFO BUFFER Landing Zone
Data transfer rate MB/S int Bytes/Sector 512
4.000 MB/S ext SYNC
Recording method RLL 2/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 45 | -20 50
Power: sleep W Humidity % 8 80 | 8 90
standby W Altitude km |
idle W Shock g 2 | 20
seek W Rotation RPM 3600
read/write W Acoustic dBA
spin-up W ECC Bit 48
MTBF h 30000
Warranty Month
Lift/Lock/Park YES Certificates
HITACHI DK514C-38 PRODUCT MANUAL K2500232
+---------------------------------------------------------+ | JP198--+1 | | +--+2 | | (PCB Rev. A/D2 or later) TM195-+++-+TM199-+ | | || | XX| | | || | XX| | | || | XX| | +--++--+ XX| | XX| | XX|J1 | JP257--+1 XX| | +--+2 XX| | XX| | +-+ | XXX J3 | 11+--------+1 JP292 XXX | 12+--------+2 | +---------------------------------------------------------+
+---------------------------------------------------------+ | JP198-+ | | +-+ | | (PCB Rev. A/D1 or former) TM195-+++-+TM199-+ | | || | XX| | | || | XX| | | || | XX| | +--++--+ XX| | XX| | XX|J1 | JP257+--++--+JP261 XX| | 2--12--1 XX| | XX| | +-+ | XXX J3 | 11+--------+1 JP292 XXX | 12+--------+2 | +---------------------------------------------------------+
HITACHI DK514C-38 PRODUCT MANUAL K 2500232
Jumper Setting
==============
x = Shipped at the factory
Jumper Plug Installation (PCB Rev. A/D2 or later)
-------------------------------------------------
The following jumpers are accessible to the user (use green jumper
plugs):
JP292 Pins 7 12 SCSI ID setting jumper
JP292 Pins 5-6 SCSI bus parity jumper
JP198 Pins 1 4 Terminator power on/off
JP257 Pins 1-2 Write protection jumper
JP257 Pins 3-4 Motor Start/Stop option
NOTE
The DK514C jumpers other than listed above are installed by the manu-
facturer and must not be replaced by the user (black jumper plugs).
NOTE
The JP261 located near the JP257 is used as for Motor Start/Stop
jumper in the P/B Rev. 0 and 1 PC board. The JP261 is replaced by
JP257 (Pin 3-4) in the P/B Rev. 2 or more board.
JP292 SCSI ID setting jumper
-----------------------------
11-+-+-+-+-+1+ Pins
|X|X|X|X| | | 11-12 9-10 7-8
12-+-+-+-+-+2+ CLOSED CLOSED CLOSED SCSI ID 0 x
1 2 4 | OPEN CLOSED CLOSED SCSI ID 1
+-+-+ +SCSI Parity CLOSED OPEN CLOSED SCSI ID 2
SCSI ID OPEN OPEN CLOSED SCSI ID 3
CLOSED CLOSED OPEN SCSI ID 4
OPEN CLOSED OPEN SCSI ID 5
CLOSED OPEN OPEN SCSI ID 6
OPEN OPEN OPEN SCSI ID 7
JP292 5-6 SCSI Bus Parity Jumper
--------------------------------
5-6 OPEN Disables SCSI Bus parity
CLOSED Enables SCSI Bus parity x
JP198 1-4 Terminator power on/off jumper
----------------------------------------
+3-4+ Pins 1-2
|xxx| CLOSED +5V source for terminator is supplied from the SCSI
|o o| bus (host) (Pins 3-4 OPEN)
+1-2+ x OPEN +5V source for terminator is supplied from the
drive controller. (Pins 3-4 CLOSED)
Note: Terminator power source is supplied to the terminator register
module from the host that pulls up the SCSI interface signals in the
controller so that the SCSI bus lines will not be pulled down when
DK514C power is turned down.
JP257 1-2 Write Protected
-------------------------
1-2 CLOSED Write protected. The disk can be only read and cannot be
written.
1-2 OPEN Read or write. The disk is enabled for both read and
write. x
JP257 3-4 Motor Start/Stop jumper
---------------------------------
3-4 CLOSED The motor start/stop option is not selected. The spindle
motor is started when power is turned on. x
OPEN The motor start/stop option is selected. The spindle
motor can be started or stopped by using SCSI command.
When the motor start/stop option is selected, the drive enters the
motor stop state when its power is turned on. Use the Start/Stop Unit
(1BH) command to start or stop the drive.
NOTE
When motor start/stop option is not used, the controller does not
respond to the host about 35 sec from Power turn-on to Drive Ready.
The terminator of the DK514C other than the last drive of SCSI Daisy
Chain MUST be removed.
Jumper Plug Installation (PCB Rev. A/D1 or former)
--------------------------------------------------
The following jumpers are accessible to the user (use green jumper
plugs):
JP292 Pins 7 12 SCSI ID setting jumper
JP292 Pins 5-6 SCSI bus parity jumper
JP198 Terminator power on/off
JP257 Write protection jumper
JP261 Motor Start/Stop option
NOTE
The DK514C jumpers other than listed above are installed by the manu-
facturer and must not be replaced by the user (black jumper plugs).
NOTE
The JP261 located near the JP257 is used as for Motor Start/Stop
jumper in the P/B Rev. 0 and 1 PC board. The JP261 is replaced by
JP257 (Pin 3-4) in the P/B Rev. 2 or more board.
JP292 SCSI ID setting jumper
-----------------------------
11-+-+-+-+-+1+ Pins
|X|X|X|X| | | 11-12 9-10 7-8
12-+-+-+-+-+2+ CLOSED CLOSED CLOSED SCSI ID 0 x
1 2 4 | OPEN CLOSED CLOSED SCSI ID 1
+-+-+ +SCSI Parity CLOSED OPEN CLOSED SCSI ID 2
SCSI ID OPEN OPEN CLOSED SCSI ID 3
CLOSED CLOSED OPEN SCSI ID 4
OPEN CLOSED OPEN SCSI ID 5
CLOSED OPEN OPEN SCSI ID 6
OPEN OPEN OPEN SCSI ID 7
JP292 5-6 SCSI Bus Parity Jumper
--------------------------------
5-6 OPEN Disables SCSI Bus parity
CLOSED Enables SCSI Bus parity x
JP198 Terminator power on/off jumper
------------------------------------
CLOSED +5V source for terminator is supplied from the SCSI
bus or the controller.
x OPEN +5V source for terminator is supplied only from the
controller.
Note: Terminator power source is supplied to the terminator register
module from the host that pulls up the SCSI interface signals in the
controller so that the SCSI bus lines will not be pulled down when
DK514C power is turned down.
JP257 Write Protected
---------------------
CLOSED Write protected. The disk can be only read and cannot be
written.
OPEN Read or write. The disk is enabled for both read and
write. x
JP261 Motor Start/Stop jumper
-----------------------------
CLOSED The motor start/stop option is not selected. The spindle
motor is started when power is turned on. x
OPEN The motor start/stop option is selected. The spindle
motor can be started or stopped by using SCSI command.
When the motor start/stop option is selected, the drive enters the
motor stop state when its power is turned on. Use the Start/Stop Unit
(1BH) command to start or stop the drive.
NOTE
When motor start/stop option is not used, the controller does not
respond to the host about 35 sec from Power turn-on to Drive Ready.
The terminator of the DK514C other than the last drive of SCSI Daisy
chain MUST be removed.
![]() |
|
|