Hard Drive: HITACHI: DK511-8 68MB 5.25"/FH MFM ST506 |
![]() |
||
![]() |
||||
![]() |
![]() |
![]() |
||
![]() |
||||
![]() |
![]() |
![]() |
![]() |
||
![]() |
||
![]() |
![]() |
![]() |
![]() |
||
|
|
||
![]() |
||
![]() |
![]() |
![]() |
![]() |
||
![]() |
||
D K 5 1 1 - 8 HITACHI
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 5.25"/FH Cylinders 823| | |
Capacity form/unform 68/ MB Heads 10| | |
Seek time / track 23.0/ ms Sector/track 17| | |
Controller MFM / ST506 Precompensation 400
Cache/Buffer KB Landing Zone 822
Data transfer rate 0.625 MB/S int Bytes/Sector 512
0.625 MB/S ext
Recording method MFM operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C |
Power: sleep W Humidity % |
standby W Altitude km |
idle W Shock g |
seek W Rotation RPM 3600
read/write W Acoustic dBA
spin-up W ECC Bit
MTBF h
Warranty Month
Lift/Lock/Park NO Certificates
HITACHI DK511 PRODUCT MANUAL K6600061 REV. 7 10/01/1985
+---------------------------------------------------------+ ++LED xxJP164 +-----+9 4--3 |XX ++ JP155 1-----8 | |JP117 |XX | 16------9 JP123 6--1 |XX J2 | 1+------+ PLO Write Prot.|XX | Velocity |XX | Gain 6--5 |XX | Write | |JP113 | | Protect | | |XX | SZ073 PCB REV. 3 +--1 |XX | Component Side +--4 |XX J1 | General xxJP70 | |JP68 |XX | Reset 8--1Drive |XX | Select |XX | +-------+ +-------+Term. | | + 5A | + IC | |xx | +-------+ +-------+ |XX | (POSN-P) TP27Ax xTP10A (GND) |XX J3 +---------------------------------------------------------+
+---------------------------------------------------------+ ++LED xxJP164 +-----+9 4--3 |XX ++ JP155 1-----8 | |JP117 |XX | 16------9 JP123 6--1 |XX J2 | 1+------+ |XX | |XX | 6--5 |XX | | |JP113 | | | | |XX | SZ073 PCB REV. 4 or 5 +--1 |XX | Component Side +--4 |XX J1 | 1xxx3 | |JP68 |XX | JP70 8--1 |XX | |XX | +-------+ +-------+Term. | | + 5A | + IC | |xx | +-------+ +-------+ |XX | (POSN-P) TP27Ax xTP10A (GND) |XX J3 +---------------------------------------------------------+
+---------------------------------------------------------+ ++LED xxx JP182A xxJP164 +-----+9 4--3 |XX ++ 1 3 JP155 1-----8 | |JP117 |XX | 16------9 JP123 6--1 |XX J2 | 1+------+ |XX | |XX | 6--5 |XX | | |JP113 | | | | |XX | SZ073 PCB REV. 6 +--1 |XX | Component Side +--4 |XX J1 | 1xxx3 | |JP68 |XX | JP70 8--1 |XX | |XX | +-------+ +-------+Term. | | + 5A | + IC | |xx | +-------+ +-------+ |XX | (POSN-P) TP27Ax xTP10A (GND) |XX J3 +---------------------------------------------------------+
+---------------------------------------------------------+ | +--+| | | || | Head Sel #7 3xxx1 |J7|| | SZ074 PCB Fault Jumper > JP4A | || | Switch +--+| | +---+| | | ++--- | +----+ | J4|| | | | | ++----- | | J8 | +---+| | | | +-+| | +----+ J5| || | | || | | || | +-+| | J6+--+ | | +--+ | +---------------------------------------------------------+
HITACHI DK511 PRODUCT MANUAL K6600061 REV. 7, 10/01/1985
Jumper Setting
==============
Adjustment
----------
There are two types of jumper switches for DK511 as follows:
CAUTION
1. Jumper Switches with GREEN connectors: to be used for an assign-
ment of unit address and for selection of optional functions, and
to be arranged when installing the unit or replacing the PC board.
2. Jumper Switches with BLACK connectors; to be used for adjusting
servo control circuits. These need not be readjusted when
installing the unit or replacing to a spare PC board since they
have already been adjusted at shipment. Even if a readjustment is
needed by all means, be sure to make a record of their preset
status prior to readjust them for the capability of recovery.
Setting of GREEN Jumper Switches
--------------------------------
JP68 Drive Select Jumper Switch
-------------------------------
There is the jumper switch to select the drive address number. Set up
the switch as follows:
8 7 6 5 8 7 6 5 8 7 6 5 8 7 6 5
+-------+ +-------+ +-------+ +-------+
|X o o o| |o X o o| |o o X o| |o o o X|
|X o o o| |o X o o| |o o X o| |o o o X|
+-------+ +-------+ +-------+ +-------+
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
Drive 0 Drive 1 Drive 2 Drive 3
As shipped, the jumper pins 1 to 8 is shorted for Drive 0.
Jumper for Optional Functions
-----------------------------
General Reset Jumper Switch
As an optional feature, there is General Reset signal (J1-2 pin)
which can be available by the jumper switch (JP70 on SZ073 PCB REV. 3
SZ073 PCB REV. 4 or 5, SZ073 PCB REV. 6 ).
Set up the jumper switch as follows:
General Reset Jumper Switch SZ073 PCB REV. 3
JP70 JP70
+-+ +-+
|o| J1-2 pin is OPEN |X| General Reset Signal is available
|o| |X|
+-+ +-+
Primary Optional
When shipped the jumper is set to the primary position.
General Reset Jumper Switch SZ073 PCB REV. 4
JP70 JP70
+-+ +-+
|X|1 J1-2 pin is OPEN |o| General Reset Signal is available
|X|2 |X|
|o|3 |X|
+-+ +-+
Primary Optional
When shipped the jumper is set to the primary position.
Write Protect Jumper Switch
---------------------------
As an optional feature, there are WRITE PROTECT (J2-7 Pin) and
WRITE PROTECTED signal (J2-11 pin) which can be available by the
jumper switches (JP113 and JP117). Setting up these jumper switches
are as follows:
Primary
-------
JP113 JP117
10-------6+ +6---4+ JP113 J2-7 pin is connected to J1-16 pin.
|o X o o o| |o o o| JP117 J2-11 pin is GND.
|o X o o o| |o xxx|
+1-------5+ +1---3+
Optional
--------
JP113 JP117
10-------6+ +6---4+ JP113 Write Protect signal is available.
|o o o o o| |o X o| JP117 Write Protected signal is available.
|xxx o o o| |o X o|
+1-------5+ +1---3+
When shipped, these jumpers are set in the primary position.
JP182A LED Jumper Switch
------------------------
There is the jumper switch (SZ073 PCB REV. 6 ) deactivating the
green LCD.
Primary Optional
------- --------
+-+ +-+
1|X| LED activated 1|o| LED deactivated (OFF)
2|X| 2|X|
3|o| 3|X|
+-+ +-+
When shipped, this jumper is set in the primary position.
Terminator
----------
If the multiple drives are connected in the daisy chain mode, only
the last drive must be terminated with a terminator module. When
shipped, the terminator module (IC#IC) is installed. Remove it all
but the last drive (if the multiple drives in the daisy chain mode).
Adjustment Specification (BLACK Jumper)
---------------------------------------
NOTE
Since adjustment portions are already adjusted when the device is
shipped, don't move them unless understanding the prior "CAUTION"
of this chapter.
JP4A Head Sel #7 Fault Jumper Switch
------------------------------------
(This jumper is available from SZ073 Rev. 7)
Write Fault caused by invalid head selection is ignored by this
option. If this option doesn't use, the selection of HD#7 causes
Write Fault. This option is available on and after SZ073 REV. 7.
Primary Optional
------- --------
+-+ JP4A +-+ JP4A
1|o| HD#7 selection 1|x| HD#7 selection doesn't
2|X| causes Write 2|X| causes Write Fault.
3|X| Fault. 3|o|
+-+ +-+
When shipped, this jumper is set in the primary position.
PLO free-running frequency -------------------------- - Pull J6 Connector and insert Jumper socket in JP164 for allowing the error signal to set at zero.
- Turn the power on, and adjust the value of JP117-6 pin within the range of 10 MHz 1% using JP123.
- After completion of aforementioned adjustment, turn the power off, insert J6 Connector in the original position, and then pull Jumper Socket out of JP164.
- Turn the power on again and ensure that an operation is in normal status (device in READY status).
![]() |
|
|