Articles / TULARC / PC info / Hard Drives / HITACHI Hard Drives / | ![]() |
|
![]() |
||||
![]() |
![]() |
|||
![]() |
![]() |
|||
![]() |
||||
|
|
||||
![]() |
![]() |
|||
![]() |
Hard Drive: HITACHI: DK318H-91WC 9100MB 3.5"/HH SCSI3 W/UL |
![]() |
||
![]() |
||||
![]() |
![]() |
![]() |
||
![]() |
||||
![]() |
![]() |
![]() |
![]() |
||
![]() |
||
![]() |
![]() |
![]() |
![]() |
||
|
|
||
![]() |
||
![]() |
![]() |
![]() |
![]() |
||
![]() |
||
D K 3 1 8 H - 9 1 W C HITACHI
Native| Translation
------+-----+-----+-----
Form 3.5"/HH Cylinders | | |
Capacity form/unform 9100/ MB Heads 20| | |
Seek time / track 9.0/ 1.0 ms Sector/track | | |
Controller SCSI3 SI/WI/ULTR/SCA Precompensation
Cache/Buffer 512 KB Landing Zone
Data transfer rate 10.000 MB/S int Bytes/Sector 512
40.000 MB/S ext SYNC
Recording method PRML 8/9 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 50 | -40 60
Power: sleep W Humidity % 8 80 | 8 90
standby W Altitude km 2.500| 12.000
idle W Shock g 5 | 50
seek 12.2 W Rotation RPM 7198
read/write W Acoustic dBA 45
spin-up W ECC Bit
MTBF h 1000000
Warranty Month
Lift/Lock/Park YES Certificates
HITACHI DK318H-91WC JUMPER SETTING
+---------------------------------------------------------+ | | | | | | | XXX | XXX | XXX | 2++++++ XXX | 1++++++ JP2 XXX | XXX | XXX | XXX | +-+ XXX | | |JP3 XXX | | | | | 2-1 | | | +---------------------------------------------------------+
+---------------------------------------------------------+ | ++++++1 | | RESERVED ++++++2 | | J6 | | | | | | | | | | | | | | | | | | | | | | | | | | | +---------------------------------------------------------+
HITACHI DK318H-91WC JUMPER SETTING
Jumper Setting
==============
NOTE
The DK318H jumpers other than listed above (BLACK jumper) are
installed by the manufacturer and must not be replaced by the user!
Never remove any of the BLACK factory set jumpers.
These jumpers are unique to each drive.
All jumpers should be set with power off.
JP2
----
2--+--+--+--+--+
|XX| |XX|XX|XX| XX = FACTORY SET
1--+--+--+--+--+
+ Write Protect
JP3 --- +--+ Disable SCSI Bus Parity +--+ Factory Set +--+ Not Used +--+ RESERVED +--+ Not Used 2--1
NOTE
1. Green jumper sockets are used for the customer's selection.
2. Shaded Jumper sockets are default setting at the factory.
3. Jumper sockets JUP2-1, 2, 5, 6, 7, 8, 9, 10 are used at the
factory with Black Jumper sockets.
Installing or removing these black jumpers will void any
warranties of the HDD.
4. In the case of SCA WIDE (16-bit) single-ended model, all of the
jumper sockets for J6 connector are removed as a default so that
the SCSI ID setting can be done by a command from host via the J1
connector.
JP3 9-10 SCSI Bus parity check
-------------------------------
9-10 OPEN Enable SCSI Bus parity check (default)
CLOSED Disable SCSI Bus parity check
JP2 3-4 Write Protect
----------------------
3-4 OPEN Write enabled (default)
CLOSED Write protected
![]() |
|
|