M 2 2 2 6 D FUJITSU NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 3.5"/HH Cylinders 615| | | Capacity form/unform 30/ 38 MB Heads 6| | | Seek time / track 40.0/ ms Sector/track 32| | | Controller MFM / ST506 Precompensation 65535 Cache/Buffer KB Landing Zone Data transfer rate 0.625 MB/S int Bytes/Sector 256 0.625 MB/S ext Recording method MFM operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 45 | -40 60 Power: sleep W Humidity % 20 80 | 5 95 standby 13.8 W Altitude km 3.000| 12.000 idle W Shock g 3 | 20 seek W Rotation RPM 3600 read/write W Acoustic dBA 43 spin-up W ECC Bit MTBF h 30000 Warranty Month Lift/Lock/Park NO Certificates
FUJITSU M222XD DISK DRIVES OEM MANUAL B03P-4815-0003A...01
+------------------------------------------------------+ | SW1--+|xx B cable | Terminator | ||xx card | Drive mode | ||xx edge | SW8--+|xx | +-+|xx | Daisy-chain |D||xx | Radial |R||xx | Drive 4 |4|| | Drive 3 |3||xx A cable | Drive 2 |2||xx card | Drive 1 |1||xx edge | +-+|xx | |xx | |xx | | | |XX Power | |XX +------------------------------------------------------+
FUJITSU M222XD DISK DRIVES OEM MANUAL B03P-4815-0003A...01
Jumper Settings
===============
x = Jumper is set from factory
Drive select
------------
Set one of the drive number (1 to 4) with the short plug as
follows.
1 2 3 4 R D +--+--+--+--+--+--+ |XX| | | | |XX| ++-+-++-++-++--+--+ | | | +----------------- Drive select = DRIVE 4 | | +-------------------- = DRIVE 3 | +----------------------- = DRIVE 2 +--------------------------- = DRIVE 1 x
Radial/daisy connection setting
-------------------------------
1 2 3 4 R D +--+--+--+--+--+--+ |XX| | | | |XX| +--+--+--+--++-+-++ | +---------- Short plug = Daisy connection x +-------------- Short plug = Radial connection
Set either radial or daisy connection.
Terminator connection
---------------------
1 2 3 4 5 6 7 8 +----------------+ When all switches other than SW7 are set on ON, |x x x x x x x | the terminator is connected. +----------------+
1 2 3 4 5 6 7 8 +----------------+ When all switches other than SW7 are set on OFF, |. . . . . . . | the terminator is not connected. +----------------+
Drive mode
----------
1 2 3 4 5 6 7 8 +----------------+ | . | Drive mode 1 is selected to set SW7 to OFF. +----------------+
1 2 3 4 5 6 7 8 +----------------+ | x | Drive mode 2 is selected to set SW7 to ON. +----------------+
To keep the high positioning accuracy, this drive renews the
positioning compensation data during the normal operation. This drive
has two mode, Drive mode 1 and 2, for this operation.
Drive mode 1
------------
Select drive mode 1 when the function of the connected controller
satisfies following two items.
- Read or Write operation instruction after Drive Select must be issued after confirming Seek Complete signal from the drive.
- Drive Select signal must be turned off when the drive is not accessed even if only one drive is connected.
For this mode, the drive renews the compensation data after Drive
Select signal becomes false. During this opertion, Seek Complete
signal is false. Then the controller changes Drive Select signal to
true, and the read and write operation is executed after Seek
Complete signal becomes true.
Drive mode 2
------------
When the controller does not have the the function of Drive mode 1,
select Drive mode 2.
In this mode, when the drive detects the renewal requirement for
the positioning compensation data, the drive stops to send data on
MFM RD data line and waits the retry operation instruction (read
retry and recalibration) from the controller, then executes the
renewal operation at the recalibration operation. Seek Complete
signal is in false state or 1 second maximum.
When the drive receives Seek command before executing the retry
operation, the drive executes the renewal operation at the recalibra-
tion operation. Seek Complete signal is in false state for 1 second
maximum.
FUJITSU M222XD DISK DRIVES OEM MANUAL B03P-4815-0003A-01
Notes on installation
=====================
Drive mounting
--------------
horizontally vertically +-----------------+ +--+ +--+ +------------------+ | | | +-----+ +-----+ | | | x | | | | | | | | x+----------------+x +-+-----------------+-+ | | | | | | ||x x|| +---------------------+ | | | | | | || x x || | | | | | | || x x || x x | | | | | | || x x || +------x------x-------+ | +-----+ +-----+ | || xx || +-+------x--x-------+-+ +--+ +--+ || x x || | xx | || x x || | x x | || x x || +---x--------x----+ |x x| x x x++----------------++x UNACCEPTABLE! UNACCEPTABLE! Never install PC board on the Top!
The drive may be installed in a system cabinet either vertically or
horizontally, except the horizontal position with the PCB on top and
the vertical position on end.
In this case, installation horizontal rate shall be within 20
degrees.
However, when inclines as the disk side comes lower side,
installation horizontal rate shall be within 5 degrees.
Ambient temperature
-------------------
The operating temperature range of the drive is specified at a dis-
tance of 3 cm from the drive. The operating temperature should not
exceed 45*C with considering cooling air flow. To satisfy above
condition, the base surface temperature under the Ready condition
should not exceed 63*C. The PCA should be cooled especially with
proper air circulation in the cabinet.
Daisy chain connection
----------------------
+-------------+ A cable +--------------+ | +----------*---+ Drive 1 +----+ | +----------+---+ | | | | B cable | +--------------+ | | | *---+ Drive 2 +---+| | +----------+---+ | || | Controller | B cable | +--------------+ || | | *---+ Drive 3 +--+|| | +----------+---+ | ||| | | B cable | +--------------+ ||| | | +---XX Terminator +-+||| | +--------------+ Drive 4 | |||| | | B cable +--------------+ |||| | | |||| +-------------+ |||| | +-----Power-cable---------------+||| | POWER +----------Power-cable-----------+|| | SUPPLY +---------------Power-cable-------+| | +--------------------Power-cable---+ +-------------+
Connection of drive to its controller is shown in that figure. The
A cable (control signals) must be connected in series and the B
cable (R/W signals) in parallel. The termination of control signal
must be performed only at the last drive.
Radial connection
-----------------
+-------------+ +--------------+ | +------A-------XX Terminator +----+ | +------B-------+ Drive 1 | | | | +--------------+ | | +------A-------XX Terminator +---+| | +------B-------+ Drive 2 | || | Controller | +--------------+ || | +------A-------XX Terminator +--+|| | +------B-------+ Drive 3 | ||| | | +--------------+ ||| | +------A-------XX Terminator +-+||| | +------B-------+ Drive 4 | |||| | | +--------------+ |||| | | |||| +-------------+ |||| | +-----Power-cable---------------+||| | POWER +----------Power-cable-----------+|| | SUPPLY +---------------Power-cable-------+| | +--------------------Power-cable---+ +-------------+ Connection of drive to its controller is shown in that Figure. The A cable (control signals) and the B cable (R/W signals) must be connected in parallel. The termination of control signal must be performed at all drives.
Cable connector specification ----------------------------- +----------+----------------+-----------------+------------------+ |Connector |Name |Spec. No. |Manufacturer | +----------+----------------+-----------------+------------------+ | |Cable |FCN-767J034-AU/1 |FUJISTU | | |Connector |or 88373-3 |AMP | |A cable | |or 3463-0001 |3M | |34 pin +----------------+-----------------+------------------+ | |Drive card edge |----- |----- | | +----------------+-----------------+------------------+ | |Cable |455-248-34 |Spectra-Strip | | | |or 171-34 |Ansley | +----------+----------------+-----------------+------------------+ | |Cable |FCN-767J020-AU/1 |FUJISTU | | |Connector |or 88373-6 |AMP | |B cable | |or 3461-0001 |3M | |20 pin +----------------+-----------------+------------------+ | |Drive card edge |----- |----- | | +----------------+-----------------+------------------+ | |Cable |455-248-20 |Spectra-Strip | | | |or 171-20 |Ansley | +----------+----------------+-----------------+------------------+ | |Cable Connector |1-480424-0 |AMP | | +----------------+-----------------+------------------+ |Power |Drive Connector |1-350211-1 |AMP | |cable +----------------+-----------------+------------------+ | |Contact |170121-4 |AMP | | +----------------+-----------------+------------------+ | |Cable |AWG 18 (+ 5V RTN)|---- | | | |AWG 18 (+12V RTN)| | +----------+----------------+-----------------+------------------+
Power cable ----------- +-----------------+ 1 = +12 V | 4 3 2 1 | 2 = +12 V RTN +-----------------+ 3 = + 5 V RTN 4 = + 5 V
FUJITSU M222XD DISK DRIVES OEM MANUAL B03P-4815-0003A...01
Start and stop time
-------------------
Start time (time from when power is turned on until the drive is
ready) is 15 seconds or less and stop time (time to completely stop
when power is turned off) is 25 seconds or less.
AC line noise
-------------
To eliminate AC line noise, a noise filter should be incorporated in
the AC input terminal of the drive power supply.
Attenuation characteristics: 40 dB or grater at 10MHz
Circuit configuration: T type
Media error
-----------
Cylinder 0, Head 0 7 are defect free.
The number of defect in the M222XD are as follows:
M2226D ..... max. 38 M2227D ..... max. 51
Mean Time Between Failures (MTBF)
---------------------------------
The estimated MTBF of this drive during its life time is 30,000 hours
after an initial 3-month period.
Mean Time To Repair
-------------------
MTTR is the average time taken by well-trained service mechanic to
diagnose and repair a unit malfunction. This drive is designed for a
MTTR of 30 minutes or less.
Service life
------------
Overhaul of this drive is not required for the first five years.
Power loss
----------
Integrity of the data on the disk is guaranteed against all forms of
abnormal DC power failure except a power failure during writing.
Write Precompensation
---------------------